Novel quantitative assessment system of liver steatosis using a newly developed attenuation measurement method. Issue 10 (18th May 2018)
- Record Type:
- Journal Article
- Title:
- Novel quantitative assessment system of liver steatosis using a newly developed attenuation measurement method. Issue 10 (18th May 2018)
- Main Title:
- Novel quantitative assessment system of liver steatosis using a newly developed attenuation measurement method
- Authors:
- Tamaki, Nobuharu
Koizumi, Yohei
Hirooka, Masashi
Yada, Norihisa
Takada, Hitomi
Nakashima, Osamu
Kudo, Masatoshi
Hiasa, Yoichi
Izumi, Namiki - Abstract:
- Abstract : Aim: The present study has developed and evaluated the effectiveness of a new echo attenuation measurement function combined with an ultrasonic diagnostic system for the accurate diagnosis of liver steatosis. Methods: A multicenter prospective study involving patients with chronic hepatitis was carried out. All patients underwent liver biopsy, and attenuation coefficient (ATT) was measured on the same day. The fat area (%) of biopsy specimens was quantitatively evaluated. Correlations between ATT, steatosis grade, and fat area were evaluated. Results: A total of 351 patients were enrolled in this study. The median values of fat area for steatosis grades S0, S1, S2, and S3 were 0.6%, 3.2%, 6.4%, and 15.5%, respectively. A significant correlation was found between fat area and steatosis grade ( P < 0.001). Similarly, the median values of ATT for steatosis grades S0, S1, S2, and S3 were 0.55, 0.63, 0.69, and 0.85 dB/cm/MHz, respectively, and ATT increased with an increase in the steatosis grade ( P < 0.001). Attenuation coefficient was significantly correlated with fat area (r = 0.50, P < 0.001). The area under the receiver operating characteristic curve corresponding to S ≥ 1, S ≥ 2, and S ≥ 3 were 0.79, 0.87, and 0.96, respectively. Similarly, the sensitivity and specificity of S ≥ 1, S ≥ 2, and S ≥ 3 were 72%, 82%, and 87% and 72%, 82%, and 89%, respectively. Conclusions: The newly developed ATT measurement for evaluation of liver steatosis was closelyAbstract : Aim: The present study has developed and evaluated the effectiveness of a new echo attenuation measurement function combined with an ultrasonic diagnostic system for the accurate diagnosis of liver steatosis. Methods: A multicenter prospective study involving patients with chronic hepatitis was carried out. All patients underwent liver biopsy, and attenuation coefficient (ATT) was measured on the same day. The fat area (%) of biopsy specimens was quantitatively evaluated. Correlations between ATT, steatosis grade, and fat area were evaluated. Results: A total of 351 patients were enrolled in this study. The median values of fat area for steatosis grades S0, S1, S2, and S3 were 0.6%, 3.2%, 6.4%, and 15.5%, respectively. A significant correlation was found between fat area and steatosis grade ( P < 0.001). Similarly, the median values of ATT for steatosis grades S0, S1, S2, and S3 were 0.55, 0.63, 0.69, and 0.85 dB/cm/MHz, respectively, and ATT increased with an increase in the steatosis grade ( P < 0.001). Attenuation coefficient was significantly correlated with fat area (r = 0.50, P < 0.001). The area under the receiver operating characteristic curve corresponding to S ≥ 1, S ≥ 2, and S ≥ 3 were 0.79, 0.87, and 0.96, respectively. Similarly, the sensitivity and specificity of S ≥ 1, S ≥ 2, and S ≥ 3 were 72%, 82%, and 87% and 72%, 82%, and 89%, respectively. Conclusions: The newly developed ATT measurement for evaluation of liver steatosis was closely correlated with steatosis grade and automated quantification of fat area, and it provides clinically relevant information. … (more)
- Is Part Of:
- Hepatology research. Volume 48:Issue 10(2018)
- Journal:
- Hepatology research
- Issue:
- Volume 48:Issue 10(2018)
- Issue Display:
- Volume 48, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2018-0048-0010-0000
- Page Start:
- 821
- Page End:
- 828
- Publication Date:
- 2018-05-18
- Subjects:
- attenuation measurement -- liver steatosis -- NAFLD
Liver -- Diseases -- Periodicals
Liver Diseases -- Periodicals
Foie -- Maladies -- Périodiques
616.362 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09284346 ↗
http://firstsearch.oclc.org/journal=1386-6346;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1872-034X ↗
http://www.sciencedirect.com/science/journal/13866346 ↗
http://www3.interscience.wiley.com/journal/118507311/home ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=hep ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/hepr.13179 ↗
- Languages:
- English
- ISSNs:
- 1386-6346
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4295.845000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7148.xml