Accuracy of CT angiography in detection of blood supply dominance of posterior cerebral artery in patients with posterior communicating artery aneurysm. Issue 6 (December 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of CT angiography in detection of blood supply dominance of posterior cerebral artery in patients with posterior communicating artery aneurysm. Issue 6 (December 2015)
- Main Title:
- Accuracy of CT angiography in detection of blood supply dominance of posterior cerebral artery in patients with posterior communicating artery aneurysm
- Authors:
- Ahmed, Osama
Kalakoti, Piyush
Menger, Richard
Brown, Benjamin
Zhang, Shihao
Guthikonda, Bharat
Cuellar, Hugo - Abstract:
- Background and purpose: The use of computed tomography angiography (CTA) as the sole vascular imaging study for preoperative planning for clipping of aneurysms is well described in the literature. CTA is widely available, provides quick acquisition, has low morbidity, and low cost. In this study, we describe the accuracy of CTA in determining the blood supply dominance in comparison to standard digital subtraction angiography. Materials and methods: Sixty-six patients, with both CTAs and angiograms, were reviewed by two independent neuroradiologists. The posterior cerebral artery was determined to have dominant supply from the posterior communicating artery if it was of similar size to the P2 segment and the P1 segment was smaller by approximately 50%. If the posterior communicating artery and P1 segment were the same size, it was considered to have a dual supply. If P1 and P2 segments were the same caliber and the posterior communicating artery was smaller by 50%, it was deemed to have posterior circulation dominance. Results: Based on the findings of our reviewers, CTA had a sensitivity and specificity of 69% and 96%, respectively, in predicting the presence of a fetal PCA. The positive predictive value was found to be 82% while a negative predictive value was estimated as 93%. A small-caliber P1 segment and large-caliber posterior communicating artery led to inaccurate interpretations of the CTAs. Conclusion: This study shows that one cannot accurately predict bloodBackground and purpose: The use of computed tomography angiography (CTA) as the sole vascular imaging study for preoperative planning for clipping of aneurysms is well described in the literature. CTA is widely available, provides quick acquisition, has low morbidity, and low cost. In this study, we describe the accuracy of CTA in determining the blood supply dominance in comparison to standard digital subtraction angiography. Materials and methods: Sixty-six patients, with both CTAs and angiograms, were reviewed by two independent neuroradiologists. The posterior cerebral artery was determined to have dominant supply from the posterior communicating artery if it was of similar size to the P2 segment and the P1 segment was smaller by approximately 50%. If the posterior communicating artery and P1 segment were the same size, it was considered to have a dual supply. If P1 and P2 segments were the same caliber and the posterior communicating artery was smaller by 50%, it was deemed to have posterior circulation dominance. Results: Based on the findings of our reviewers, CTA had a sensitivity and specificity of 69% and 96%, respectively, in predicting the presence of a fetal PCA. The positive predictive value was found to be 82% while a negative predictive value was estimated as 93%. A small-caliber P1 segment and large-caliber posterior communicating artery led to inaccurate interpretations of the CTAs. Conclusion: This study shows that one cannot accurately predict blood supply dominance of the posterior cerebral artery. Knowledge of the blood flow dominance is essential when clipping a posterior communicating artery aneurysm to avoid compromise in posterior circulation. … (more)
- Is Part Of:
- Neuroradiology journal. Volume 28:Issue 6(2015:Dec.)
- Journal:
- Neuroradiology journal
- Issue:
- Volume 28:Issue 6(2015:Dec.)
- Issue Display:
- Volume 28, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 28
- Issue:
- 6
- Issue Sort Value:
- 2015-0028-0006-0000
- Page Start:
- 598
- Page End:
- 603
- Publication Date:
- 2015-12
- Subjects:
- CT imaging -- CT angiography -- posterior cerebral artery -- digital subtraction angiography
Nervous system -- Radiography -- Periodicals
Neuroradiography -- Periodicals
Electronic journals
616.804757 - Journal URLs:
- http://neu.sagepub.com/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/2437/ ↗
http://www.theneuroradiologyjournal.it/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1971400915615082 ↗
- Languages:
- English
- ISSNs:
- 1971-4009
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7156.xml