Safety and benefit of using a virtual bolus during treatment planning for breast cancer treated with arc therapy. (30th June 2018)
- Record Type:
- Journal Article
- Title:
- Safety and benefit of using a virtual bolus during treatment planning for breast cancer treated with arc therapy. (30th June 2018)
- Main Title:
- Safety and benefit of using a virtual bolus during treatment planning for breast cancer treated with arc therapy
- Authors:
- Tyran, Marguerite
Tallet, Agnes
Resbeut, Michel
Ferre, Marjorie
Favrel, Veronique
Fau, Pierre
Moureau‐Zabotto, Laurence
Darreon, Julien
Gonzague, Laurence
Benkemouche, Ahcene
Varela‐Cagetti, Leonel
Salem, Naji
Farnault, Bertrand
Acquaviva, Marie‐Aimee
Mailleux, Hugues - Abstract:
- Abstract: Purpose: This study evaluates the benefit of a virtual bolus method for volumetric modulated arc therapy (VMAT) plan optimization to compensate breast modifications that may occur during breast treatment. Methods: Ten files were replanned with VMAT giving 50 Gy to the breast and 47 Gy to the nodes within 25 fractions. The planning process used a virtual bolus for the first optimization, then the monitors units were reoptimized without bolus, after fixing the segments shapes. Structures and treatment planning were exported on a second scanner (CT) performed during treatment as a consequence to modifications in patient's anatomy. The comparative end‐point was clinical target volume's coverage. The first analysis compared the VMAT plans made using the virtual bolus method (VB‐VMAT) to the plans without using it (NoVB‐VMAT) on the first simulation CT. Then, the same analysis was performed on the second CT. Finally, the level of degradation of target volume coverage between the two CT using VB‐VMAT was compared to results using a standard technique of forward‐planned multisegment technique (Tan‐IMRT). Results: Using a virtual bolus for VMAT does not degrade dosimetric results on the first CT. No significant result in favor of the NoVB‐VMAT plans was noted. The VB‐VMAT method led to significant better dose distribution on a second CT with modified anatomies compared to NoVB‐VMAT. The clinical target volume's coverage by 95% (V95%) of the prescribed dose was 98.9%Abstract: Purpose: This study evaluates the benefit of a virtual bolus method for volumetric modulated arc therapy (VMAT) plan optimization to compensate breast modifications that may occur during breast treatment. Methods: Ten files were replanned with VMAT giving 50 Gy to the breast and 47 Gy to the nodes within 25 fractions. The planning process used a virtual bolus for the first optimization, then the monitors units were reoptimized without bolus, after fixing the segments shapes. Structures and treatment planning were exported on a second scanner (CT) performed during treatment as a consequence to modifications in patient's anatomy. The comparative end‐point was clinical target volume's coverage. The first analysis compared the VMAT plans made using the virtual bolus method (VB‐VMAT) to the plans without using it (NoVB‐VMAT) on the first simulation CT. Then, the same analysis was performed on the second CT. Finally, the level of degradation of target volume coverage between the two CT using VB‐VMAT was compared to results using a standard technique of forward‐planned multisegment technique (Tan‐IMRT). Results: Using a virtual bolus for VMAT does not degrade dosimetric results on the first CT. No significant result in favor of the NoVB‐VMAT plans was noted. The VB‐VMAT method led to significant better dose distribution on a second CT with modified anatomies compared to NoVB‐VMAT. The clinical target volume's coverage by 95% (V95%) of the prescribed dose was 98.9% [96.1–99.6] on the second CT for VB‐VMAT compared to 92.6% [85.2–97.7] for NoVB‐VMAT ( P = 0.0002). The degradation of the target volume coverage for VB‐VMAT is not worse than for Tan‐IMRT: the median differential of V95% between the two CT was 0.9% for VMAT and 0.7% for Tan‐IMRT ( P = 1). Conclusion: This study confirms the safety and benefit of using a virtual bolus during the VMAT planning process to compensate potential breast shape modifications. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 5(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 5(2018)
- Issue Display:
- Volume 19, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 5
- Issue Sort Value:
- 2018-0019-0005-0000
- Page Start:
- 463
- Page End:
- 472
- Publication Date:
- 2018-06-30
- Subjects:
- breast -- radiotherapy -- skin flash -- virtual bolus -- VMAT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12398 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7137.xml