A COMPARISON STUDY BETWEEN MOBIL-O-GRAPH AND SPHYGMOCOR DEVICES IN ASSESSING AORTIC SYSTOLIC PRESSURE AND PULSE WAVE VELOCITY IN PERITONEAL DIALYSIS PATIENTS. (June 2018)
- Record Type:
- Journal Article
- Title:
- A COMPARISON STUDY BETWEEN MOBIL-O-GRAPH AND SPHYGMOCOR DEVICES IN ASSESSING AORTIC SYSTOLIC PRESSURE AND PULSE WAVE VELOCITY IN PERITONEAL DIALYSIS PATIENTS. (June 2018)
- Main Title:
- A COMPARISON STUDY BETWEEN MOBIL-O-GRAPH AND SPHYGMOCOR DEVICES IN ASSESSING AORTIC SYSTOLIC PRESSURE AND PULSE WAVE VELOCITY IN PERITONEAL DIALYSIS PATIENTS
- Authors:
- Georgianos, P.
Vaios, V.
Pikilidou, M.
Papagianni, A.
Zebekakis, P.
Liakopoulos, V. - Abstract:
- Abstract : Objective: The newly-introduced Mobil-O-Graph monitor has been validated against invasive and non-invasive measurements of aortic systolic pressure (aSBP) and pulse wave velocity (PWV) in the general hypertensive population. However, the validity of Mobil-O-Graph-derived measurements among patients on peritoneal dialysis (PD) remains unclear. The aim of this study is to compare oscillometric measurements of aSBP, heart-rate adjusted augmentation index (AIx75) and PWV obtained with the Mobil-O-Graph monitor (IEM, Germany) against tonometric measurements taken with the Sphygmocor device (ArtCor, Australia) in patients receiving long-term PD. Design and method: A comparison study of 27 consecutive PD patients using the Sphygmocor-derived aSBP, AIx75 and PWV as reference standard. After a 10-min rest in the supine position, we applied the Mobil-O-Graph and Sphygmocor devices in a randomized order. Brachial BP recordings taken with a conventional sphygmomanometer were used to calibrate the Sphygmocor device. Results: Measurements of aSBP, AIx75 and PWV obtained with the Mobil-O-Graph device did not differ from relevant measurements taken with Sphygmocor (120.5 ± 18.2 vs 124.4 ± 19.0 mmHg, P = 0.438 for aoSBP, 27.0 ± 12.4 vs 24.5 ± 10.6%, P = 0.428 for AIx75 and 9.5 ± 2.1 vs 10.1 ± 3.1 m/sec, P = 0.397 for PWV). The slight difference in estimation of aSBP is possibly explained by the numerically higher brachial SBP values used for the calibration of SphygmocorAbstract : Objective: The newly-introduced Mobil-O-Graph monitor has been validated against invasive and non-invasive measurements of aortic systolic pressure (aSBP) and pulse wave velocity (PWV) in the general hypertensive population. However, the validity of Mobil-O-Graph-derived measurements among patients on peritoneal dialysis (PD) remains unclear. The aim of this study is to compare oscillometric measurements of aSBP, heart-rate adjusted augmentation index (AIx75) and PWV obtained with the Mobil-O-Graph monitor (IEM, Germany) against tonometric measurements taken with the Sphygmocor device (ArtCor, Australia) in patients receiving long-term PD. Design and method: A comparison study of 27 consecutive PD patients using the Sphygmocor-derived aSBP, AIx75 and PWV as reference standard. After a 10-min rest in the supine position, we applied the Mobil-O-Graph and Sphygmocor devices in a randomized order. Brachial BP recordings taken with a conventional sphygmomanometer were used to calibrate the Sphygmocor device. Results: Measurements of aSBP, AIx75 and PWV obtained with the Mobil-O-Graph device did not differ from relevant measurements taken with Sphygmocor (120.5 ± 18.2 vs 124.4 ± 19.0 mmHg, P = 0.438 for aoSBP, 27.0 ± 12.4 vs 24.5 ± 10.6%, P = 0.428 for AIx75 and 9.5 ± 2.1 vs 10.1 ± 3.1 m/sec, P = 0.397 for PWV). The slight difference in estimation of aSBP is possibly explained by the numerically higher brachial SBP values used for the calibration of Sphygmocor (131.0 ± 20.6 vs 134.5 ± 19.7 mmHg, P = 0.525). Mobil-O-Graph-derived parameters were strongly and significantly correlated with paired measurements taken with Sphygmocor (r = 0.889, P < 0.001 for aSBP, r = 0.816, P < 0.001 for AIx75 and r = 0.794, P < 0.001 for PWV). Bland-Altman plots showed no evidence of asymmetry and wide range of agreement between the two devices. Conclusions: This study suggests that oscillometric measurements of aSBP, AIx75 and PWV taken under static conditions with the Mobil-O-Graph monitor are closely related to tonometric measurements taken with the widely applied Sphygmocor device among patients on PD. The use of the Mobil-O-Graph monitor may facilitate the accurate determination of arterial stiffness indexes under ambulatory conditions in this population. … (more)
- Is Part Of:
- Journal of hypertension. Volume 36(2018)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 36(2018)Supplement 1
- Issue Display:
- Volume 36, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2018-0036-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-06
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000539196.76568.7c ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7146.xml