Combining cross-reactivity of an electrode array with the selective thiol reporting process of redox indicators: targeted sensing of biothiols. Issue 29 (6th July 2018)
- Record Type:
- Journal Article
- Title:
- Combining cross-reactivity of an electrode array with the selective thiol reporting process of redox indicators: targeted sensing of biothiols. Issue 29 (6th July 2018)
- Main Title:
- Combining cross-reactivity of an electrode array with the selective thiol reporting process of redox indicators: targeted sensing of biothiols
- Authors:
- Indherjith, Sakthinathan
Selvakumar, Karuthapandi - Abstract:
- Abstract : Combining the cross-reactivity of the voltammetric sensor array with the selective thiol reporting process of redox indicators (RIs) enables the targeted sensing of biothiols. Abstract : This paper describes the syntheses, characterization, and electro-analytical applications of metallophthalocyanine and metallophthalocyanine embedded GO/rGO materials, named CuPc (1 ), MnPc (2 ), GO–CuPc–PDA (3 ), GO–MnPc–PDA (4 ), rGO–CuPc–PDA (5 ), and rGO–MnPc–PDA (6 ) (where CuPc = copper phthalocyanine, MnPc = manganese phthalocyanine, GO = graphene oxide, rGO = reduced graphene oxide, and PDA = polydopamine). The synthesized materials were dip coated over a glassy carbon electrode (GCE) surface to yield an array of six electrodes (1′–6′ ). Each of the electrodes has shown distinct voltammetric oxidation signals towards different biothiols, such as cysteine (Cys), glutathione (GSH), and homocysteine (Hcys). The collective response of the electrode array was analyzed using chemometric analysis, such as linear discriminant analysis (LDA), which enables the simultaneous detection of Cys, GSH, and Hcys in a phosphate buffer. However, the application of the electrode array technique to the biomarker detection is often complicated due to the non-specific interference of protein components present in biofluids. We demonstrate a proof-of-principle that such interference in discriminatory sensing of thiols can be circumvented via combining the cross-reactivity of the electrode arrayAbstract : Combining the cross-reactivity of the voltammetric sensor array with the selective thiol reporting process of redox indicators (RIs) enables the targeted sensing of biothiols. Abstract : This paper describes the syntheses, characterization, and electro-analytical applications of metallophthalocyanine and metallophthalocyanine embedded GO/rGO materials, named CuPc (1 ), MnPc (2 ), GO–CuPc–PDA (3 ), GO–MnPc–PDA (4 ), rGO–CuPc–PDA (5 ), and rGO–MnPc–PDA (6 ) (where CuPc = copper phthalocyanine, MnPc = manganese phthalocyanine, GO = graphene oxide, rGO = reduced graphene oxide, and PDA = polydopamine). The synthesized materials were dip coated over a glassy carbon electrode (GCE) surface to yield an array of six electrodes (1′–6′ ). Each of the electrodes has shown distinct voltammetric oxidation signals towards different biothiols, such as cysteine (Cys), glutathione (GSH), and homocysteine (Hcys). The collective response of the electrode array was analyzed using chemometric analysis, such as linear discriminant analysis (LDA), which enables the simultaneous detection of Cys, GSH, and Hcys in a phosphate buffer. However, the application of the electrode array technique to the biomarker detection is often complicated due to the non-specific interference of protein components present in biofluids. We demonstrate a proof-of-principle that such interference in discriminatory sensing of thiols can be circumvented via combining the cross-reactivity of the electrode array with the selective thiol reporting process of redox indicators (RIs), such as ascorbic acid (AA), dopamine (DA), and uric acid (UA). … (more)
- Is Part Of:
- Analytical methods. Volume 10:Issue 29(2018)
- Journal:
- Analytical methods
- Issue:
- Volume 10:Issue 29(2018)
- Issue Display:
- Volume 10, Issue 29 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 29
- Issue Sort Value:
- 2018-0010-0029-0000
- Page Start:
- 3602
- Page End:
- 3615
- Publication Date:
- 2018-07-06
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay00972d ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7108.xml