Determination of the isoelectric point of shortened glucagon-like peptide-1 by capillary isoelectric focusing with whole column imaging. Issue 5 (3rd September 2018)
- Record Type:
- Journal Article
- Title:
- Determination of the isoelectric point of shortened glucagon-like peptide-1 by capillary isoelectric focusing with whole column imaging. Issue 5 (3rd September 2018)
- Main Title:
- Determination of the isoelectric point of shortened glucagon-like peptide-1 by capillary isoelectric focusing with whole column imaging
- Authors:
- Fang, Junjian
Liu, Jiexin
Li, Haijing
Cheng, Jianhua
Wu, Shengming
Dong, Fangting - Abstract:
- ABSTRACT: The isoelectric point of shortened glucagon-like peptide-1, a promising new drug to therapy of type 2 diabetes, was determined using a new generation of capillary isoelectric focusing-whole column imaging. Urea was added as a solubilizer to enhance the stability and repeatability of shortened glucagon-like peptide-1. The isoelectric point of shortened glucagon-like peptide-1 measured by capillary isoelectric focusing-whole column imaging was 4.49, which was similar to the theoretical value of 4.40. Furthermore, the accuracy and repeatability of capillary isoelectric focusing-whole column imaging were investigated. The results showed that this approach provided good accuracy (bias less than 2%) and excellent repeatability (coefficients of variation less than 0.25%). The isoelectric focusing coupled with whole column imaging required only a few minutes for an assay. The study demonstrated that the capillary isoelectric focusing-whole column imaging is useful for the quality control and characterization of peptide and proteins because of its accuracy, repeatability, high performance, and high throughput.
- Is Part Of:
- Instrumentation science & technology. Volume 46:Issue 5(2018)
- Journal:
- Instrumentation science & technology
- Issue:
- Volume 46:Issue 5(2018)
- Issue Display:
- Volume 46, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2018-0046-0005-0000
- Page Start:
- 545
- Page End:
- 554
- Publication Date:
- 2018-09-03
- Subjects:
- Capillary isoelectric focusing -- isoelectric point -- shortened glucagon-like peptide-1 -- whole column imaging detection
Scientific apparatus and instruments -- Periodicals
681.2 - Journal URLs:
- http://www.tandfonline.com/toc/list20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10739149.2017.1405821 ↗
- Languages:
- English
- ISSNs:
- 1073-9149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4529.043800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7095.xml