Deep-learning Classifier With an Ultrawide-field Scanning Laser Ophthalmoscope Detects Glaucoma Visual Field Severity. Issue 7 (July 2018)
- Record Type:
- Journal Article
- Title:
- Deep-learning Classifier With an Ultrawide-field Scanning Laser Ophthalmoscope Detects Glaucoma Visual Field Severity. Issue 7 (July 2018)
- Main Title:
- Deep-learning Classifier With an Ultrawide-field Scanning Laser Ophthalmoscope Detects Glaucoma Visual Field Severity
- Authors:
- Masumoto, Hiroki
Tabuchi, Hitoshi
Nakakura, Shunsuke
Ishitobi, Naofumi
Miki, Masayuki
Enno, Hiroki - Abstract:
- Abstract : Purpose: To evaluate the accuracy of detecting glaucoma visual field defect severity using deep-learning (DL) classifier with an ultrawide-field scanning laser ophthalmoscope. Methods: One eye of 982 open-angle glaucoma (OAG) patients and 417 healthy eyes were enrolled. We categorized glaucoma patients into 3 groups according to the glaucoma visual field damage (Humphrey Field Analyzer 24-2 program) [early; −6 dB (mean deviation) or better, moderate; between −6 and −12 dB, and severe as mean deviation of −12 dB or worse]. In total, 558 images (446 for training and 112 for grading) from early OAG patients, 203 images (162 for training and 41 for grading) from moderate OAG patients, 221 images (176 for training and 45 for grading) from severe OAG patients and 417 images (333 for training and 84 for grading) from normal subjects were analyzed using DL. The area under the receiver operating characteristic curve (AUC) was used to evaluate the accuracy after 100 trials. Results: The mean AUC between normal versus all glaucoma patients was 0.872, the sensitivity was 81.3% and the specificity was 80.2%. In normal versus early OAG, mean AUC was 0.830, the sensitivity was 83.8% and the specificity was 75.3%. In normal versus moderate OAG, mean AUC was 0.864, sensitivity was 77.5%, and specificity was 90.2%. In normal versus severe OAG glaucoma mean AUC was 0.934, sensitivity was 90.9%, and specificity was 95.8%. Conclusions: Despite using an ultrawide-field scanning laserAbstract : Purpose: To evaluate the accuracy of detecting glaucoma visual field defect severity using deep-learning (DL) classifier with an ultrawide-field scanning laser ophthalmoscope. Methods: One eye of 982 open-angle glaucoma (OAG) patients and 417 healthy eyes were enrolled. We categorized glaucoma patients into 3 groups according to the glaucoma visual field damage (Humphrey Field Analyzer 24-2 program) [early; −6 dB (mean deviation) or better, moderate; between −6 and −12 dB, and severe as mean deviation of −12 dB or worse]. In total, 558 images (446 for training and 112 for grading) from early OAG patients, 203 images (162 for training and 41 for grading) from moderate OAG patients, 221 images (176 for training and 45 for grading) from severe OAG patients and 417 images (333 for training and 84 for grading) from normal subjects were analyzed using DL. The area under the receiver operating characteristic curve (AUC) was used to evaluate the accuracy after 100 trials. Results: The mean AUC between normal versus all glaucoma patients was 0.872, the sensitivity was 81.3% and the specificity was 80.2%. In normal versus early OAG, mean AUC was 0.830, the sensitivity was 83.8% and the specificity was 75.3%. In normal versus moderate OAG, mean AUC was 0.864, sensitivity was 77.5%, and specificity was 90.2%. In normal versus severe OAG glaucoma mean AUC was 0.934, sensitivity was 90.9%, and specificity was 95.8%. Conclusions: Despite using an ultrawide-field scanning laser ophthalmoscope, DL can detect glaucoma characteristics and glaucoma visual field defect severity with high reliability. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 27:Issue 7(2018)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 27:Issue 7(2018)
- Issue Display:
- Volume 27, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 7
- Issue Sort Value:
- 2018-0027-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- glaucoma -- visual field defect -- deep learning -- artificial intelligence -- machine learning -- ultrawide-field scanning laser ophthalmoscope -- optos
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000988 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7088.xml