Catheter-assisted 360-Degree Trabeculotomy for Congenital Glaucoma. Issue 7 (July 2018)
- Record Type:
- Journal Article
- Title:
- Catheter-assisted 360-Degree Trabeculotomy for Congenital Glaucoma. Issue 7 (July 2018)
- Main Title:
- Catheter-assisted 360-Degree Trabeculotomy for Congenital Glaucoma
- Authors:
- Toshev, Anani P.
Much, Martin M.
Klink, Thomas
Pfeiffer, Norbert
Hoffmann, Esther M.
Grehn, Franz - Abstract:
- Abstract : Purpose: To determine feasibility, efficacy, and safety of ab externo 360-degree trabeculotomy with illuminated microcatheter for congenital glaucoma. Patients and Methods: The postoperative results of 36 eyes in 23 consecutive patients who underwent 360-degree trabeculotomy for primary congenital glaucoma (PCG) or secondary congenital glaucoma using an illuminated microcatheter were retrospectively analyzed. Success criteria were defined as intraocular pressure (IOP) ⩽18 mm Hg without (complete success) and with medication (qualified success). Results: In all previously nonoperated eyes with PCG (group 1), the Schlemm's canal was identified and circumferentially cannulated for 360-degree trabeculotomy. In group 2 comprising of operated eyes with PCG and eyes with secondary congenital glaucoma, the performance of 360-degree trabeculotomy failed in 4 eyes because of the Schlemm's canal occlusion or high tissue resistance of the trabecular meshwork. Mean preoperative IOP was 28.6±5 and 29.6±9 mm Hg with 7 of 20 eyes and 7 of 9 eyes receiving IOP-lowering medication in group 1 and group 2, respectively. Mean postoperative IOP was reduced to 13±2.7 and 20.2±7.1 mm Hg after a mean follow-up of 15.3 and 12.7 months with 4 of 20 eyes and 5 of 9 eyes receiving medication in group 1 and group 2, respectively. Four eyes underwent further surgery. Complete success was achieved in 16 and 3 eyes, whereas qualified success was achieved in 20 and 4 eyes from group 1 and group 2,Abstract : Purpose: To determine feasibility, efficacy, and safety of ab externo 360-degree trabeculotomy with illuminated microcatheter for congenital glaucoma. Patients and Methods: The postoperative results of 36 eyes in 23 consecutive patients who underwent 360-degree trabeculotomy for primary congenital glaucoma (PCG) or secondary congenital glaucoma using an illuminated microcatheter were retrospectively analyzed. Success criteria were defined as intraocular pressure (IOP) ⩽18 mm Hg without (complete success) and with medication (qualified success). Results: In all previously nonoperated eyes with PCG (group 1), the Schlemm's canal was identified and circumferentially cannulated for 360-degree trabeculotomy. In group 2 comprising of operated eyes with PCG and eyes with secondary congenital glaucoma, the performance of 360-degree trabeculotomy failed in 4 eyes because of the Schlemm's canal occlusion or high tissue resistance of the trabecular meshwork. Mean preoperative IOP was 28.6±5 and 29.6±9 mm Hg with 7 of 20 eyes and 7 of 9 eyes receiving IOP-lowering medication in group 1 and group 2, respectively. Mean postoperative IOP was reduced to 13±2.7 and 20.2±7.1 mm Hg after a mean follow-up of 15.3 and 12.7 months with 4 of 20 eyes and 5 of 9 eyes receiving medication in group 1 and group 2, respectively. Four eyes underwent further surgery. Complete success was achieved in 16 and 3 eyes, whereas qualified success was achieved in 20 and 4 eyes from group 1 and group 2, respectively. In all eyes, a mild to moderate postoperative hyphema was observed. Conclusions: Ab externo catheter-assisted 360-degree trabeculotomy controls IOP in a majority of patients with congenital glaucoma after a single operation. Moderate blood reflux in the anterior chamber is considered as a common postoperative finding. We did not observe hypotony or other severe complications in our series. In 1 patient, we experienced catheter misdirection in an eye that had previously undergone trabeculotomy. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 27:Issue 7(2018)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 27:Issue 7(2018)
- Issue Display:
- Volume 27, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 7
- Issue Sort Value:
- 2018-0027-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- congenital glaucoma -- 360-degree trabeculotomy -- illuminated microcatheter -- intraocular pressure -- glaucoma
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000966 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7088.xml