Clinical Evaluation of Synovial Alpha Defensin and Synovial C-Reactive Protein in the Diagnosis of Periprosthetic Joint Infection. (18th July 2018)
- Record Type:
- Journal Article
- Title:
- Clinical Evaluation of Synovial Alpha Defensin and Synovial C-Reactive Protein in the Diagnosis of Periprosthetic Joint Infection. (18th July 2018)
- Main Title:
- Clinical Evaluation of Synovial Alpha Defensin and Synovial C-Reactive Protein in the Diagnosis of Periprosthetic Joint Infection
- Authors:
- Stone, William Z.
Gray, Chancellor F.
Parvataneni, Hari K.
Al-Rashid, Mamun
Vlasak, Richard G.
Horodyski, MaryBeth
Prieto, Hernan A. - Abstract:
- Abstract : Background: Diagnosing periprosthetic joint infection after total joint arthroplasty is often challenging. The alpha defensin test has been recently reported as a promising diagnostic test for periprosthetic joint infection. The goal of this study was to determine the diagnostic accuracy of alpha defensin testing. Methods: One hundred and eighty-three synovial alpha defensin and synovial fluid C-reactive protein (CRP) tests performed in 183 patients undergoing evaluation for periprosthetic joint infection were reviewed. Results were compared with the Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection. Results: Alpha defensin tests were performed prior to surgical treatment for infection, and 37 of these patients who had these tests were diagnosed by MSIS criteria as having infections. Among this group, the alpha defensin test had a sensitivity of 81.1% (95% confidence interval [CI], 64.8% to 92.0%) and a specificity of 95.9% (95% CI, 91.3% to 98.5%). There were 6 false-positive results, 4 of which were associated with metallosis. There were 7 false negatives, all of which were associated with either draining sinuses (n = 3) or low-virulence organisms (n = 4). A combined analysis of alpha defensin and synovial fluid CRP tests was performed in which a positive result was represented by a positive alpha defensin test and a positive synovial fluid CRP test (n = 28). Among this group, the sensitivity was calculated to be 73.0% (95% CI,Abstract : Background: Diagnosing periprosthetic joint infection after total joint arthroplasty is often challenging. The alpha defensin test has been recently reported as a promising diagnostic test for periprosthetic joint infection. The goal of this study was to determine the diagnostic accuracy of alpha defensin testing. Methods: One hundred and eighty-three synovial alpha defensin and synovial fluid C-reactive protein (CRP) tests performed in 183 patients undergoing evaluation for periprosthetic joint infection were reviewed. Results were compared with the Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection. Results: Alpha defensin tests were performed prior to surgical treatment for infection, and 37 of these patients who had these tests were diagnosed by MSIS criteria as having infections. Among this group, the alpha defensin test had a sensitivity of 81.1% (95% confidence interval [CI], 64.8% to 92.0%) and a specificity of 95.9% (95% CI, 91.3% to 98.5%). There were 6 false-positive results, 4 of which were associated with metallosis. There were 7 false negatives, all of which were associated with either draining sinuses (n = 3) or low-virulence organisms (n = 4). A combined analysis of alpha defensin and synovial fluid CRP tests was performed in which a positive result was represented by a positive alpha defensin test and a positive synovial fluid CRP test (n = 28). Among this group, the sensitivity was calculated to be 73.0% (95% CI, 55.9% to 86.2%) and the specificity was calculated to be 99.3% (95% CI, 96.2% to 99.9%). An additional combined analysis was performed where a positive result was represented by a positive alpha defensin test or positive synovial fluid CRP test (n = 64). Among this group, the sensitivity was calculated to be 91.9% (95% CI, 78.1% to 98.3%) and the specificity was calculated to be 79.5% (95% CI, 72.0% to 85.7%). Conclusions: Alpha defensin in combination with synovial fluid CRP demonstrates very high sensitivity for diagnosing periprosthetic joint infection, but may yield false-positive results in the presence of metallosis or false-negative results in the presence of low-virulence organisms. When both alpha defensin and synovial fluid CRP tests are positive, there is a very high specificity for diagnosing periprosthetic joint infection. Level of Evidence: DiagnosticLevel III . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 100:Number 14(2018)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 100:Number 14(2018)
- Issue Display:
- Volume 100, Issue 14 (2018)
- Year:
- 2018
- Volume:
- 100
- Issue:
- 14
- Issue Sort Value:
- 2018-0100-0014-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07-18
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.17.00556 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7085.xml