Tracheal injury characterized by subcutaneous emphysema and dyspnea after improper placement of a Sengstaken–Blakemore tube: A case report. Issue 30 (July 2018)
- Record Type:
- Journal Article
- Title:
- Tracheal injury characterized by subcutaneous emphysema and dyspnea after improper placement of a Sengstaken–Blakemore tube: A case report. Issue 30 (July 2018)
- Main Title:
- Tracheal injury characterized by subcutaneous emphysema and dyspnea after improper placement of a Sengstaken–Blakemore tube
- Authors:
- Wang, Hui-shan
Lin, Jie
Wang, Fei
Miao, Lin - Other Names:
- NA. section editor.
- Abstract:
- Abstract: Rationale: Tracheal injury characterized by subcutaneous emphysema and dyspnea can occur following the use of a Sengstaken–Blakemore tube. Should tracheal injury occur, it may be possible to manage resultant airway obstruction with a tracheal stent. Patient concerns: We describe the case of a 51-year-old patient who developed a tracheal injury when a Sengstaken–Blakemore tube was inadvertently inserted into the patient's trachea. Diagnoses: Liver cirrhosis, gastric-fundus variceal bleeding, tracheal injury. Interventions: Polyglycol and tissue glue were injected intravenously, and endoscopic variceal ligation was performed. A Sengstaken–Blakemore tube was used to stop the bleeding. A covered tracheal stent was placed via fiberoptic bronchoscopy to relieve the tracheal injury due to improper placement of a Sengstaken–Blakemore tube. Outcomes: After placement of the tracheal stent, the patient was able to breathe spontaneously and subsequently recovered. Lessons: Some precautions must be taken to avoid placing a Sengstaken–Blakemore tube in the trachea. If a tracheal injury occurs following misplacement of a Sengstaken–Blakemore tube, it may be possible to manage resultant airway obstruction by placing a tracheal stent. Abstract : Supplemental Digital Content is available in the text
- Is Part Of:
- Medicine. Volume 97:Issue 30(2018)
- Journal:
- Medicine
- Issue:
- Volume 97:Issue 30(2018)
- Issue Display:
- Volume 97, Issue 30 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 30
- Issue Sort Value:
- 2018-0097-0030-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- Sengstaken–Blakemore tube -- tracheal injury -- dyspnea -- subcutaneous emphysema -- tracheal stent
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000011289 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7083.xml