Comparative Analysis of Photograph-Based Clinical Goniometry to Standard Techniques. (June 2015)
- Record Type:
- Journal Article
- Title:
- Comparative Analysis of Photograph-Based Clinical Goniometry to Standard Techniques. (June 2015)
- Main Title:
- Comparative Analysis of Photograph-Based Clinical Goniometry to Standard Techniques
- Authors:
- Crasto, Jared A.
Sayari, Arash J.
Gray, Robert R-L.
Askari, Morad - Abstract:
- Background: Assessment of joint range of motion (ROM) is an accepted evaluation of disability as well as an indicator of recovery from musculoskeletal injuries. Many goniometric techniques have been described to measure ROM, with variable validity due to inter-rater reliability. In this report, we assessed the validity of photograph-based goniometry in measurement of ROM and its inter-rater reliability and compared it to two other commonly used techniques. Methods: We examined three methods for measuring ROM in the upper extremity: manual goniometry (MG), visual estimations (VE), and photograph-based goniometry (PBG). Eight motions of the upper extremity were measured in 69 participants at an academic medical center. Results: We found visual estimations and photograph-based goniometry to be clinically valid when tested against manual goniometry ( r avg. 0.58, range 0.28 to 0.87). Photograph-based measurements afforded a satisfactory degree of inter-rater reliability (ICC avg. 0.77, range 0.28 to 0.96). Conclusions: Our study supports photograph-based goniometry as the new standard goniometric technique, as it has been clinically validated, is performed with greater consistency and better inter-rater reliability when compared with manual goniometry. It also allows for better documentation of measurements and potential incorporation into medical records in direct contrast to visual estimation.
- Is Part Of:
- Hand. Volume 10:Number 2(2015)
- Journal:
- Hand
- Issue:
- Volume 10:Number 2(2015)
- Issue Display:
- Volume 10, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2015-0010-0002-0000
- Page Start:
- 248
- Page End:
- 253
- Publication Date:
- 2015-06
- Subjects:
- Range of motion -- Visual estimation -- Photograph -- Goniometry
Hand -- Surgery -- Periodicals
Hand -- Surgery
Periodicals
617.57005 - Journal URLs:
- http://www.springerlink.com/content/119980/ ↗
http://journals.sagepub.com/toc/HAN/current ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11552-014-9702-2 ↗
- Languages:
- English
- ISSNs:
- 1558-9447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4241.550050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7064.xml