Biomechanical Comparison of Double Grasping Repair versus Cross-Locked Cruciate Flexor Tendon Repair. (March 2015)
- Record Type:
- Journal Article
- Title:
- Biomechanical Comparison of Double Grasping Repair versus Cross-Locked Cruciate Flexor Tendon Repair. (March 2015)
- Main Title:
- Biomechanical Comparison of Double Grasping Repair versus Cross-Locked Cruciate Flexor Tendon Repair
- Authors:
- Dwyer, C. Liam
Dominy, D. Dean
Cooney, Timothy E.
Englund, Richard
Gordon, Leonard
Lubahn, John D. - Abstract:
- Purpose: This study was conducted to compare the in vitro biomechanical properties of tensile strength and gap resistance of a double grasping loop (DGL) flexor tendon repair with the established four-strand cross-locked cruciate (CLC) flexor tendon repair, both with an interlocking horizontal mattress (IHM) epitendinous suture. The hypothesis is that the DGL-IHM method which utilizes two looped core sutures, grasping and locking loops, and a single intralesional knot will have greater strength and increased gap resistance than the CLC-IHM method. Methods: Forty porcine tendons were evenly assigned to either the DGL-IHM or CLC-IHM group. The tendon repair strength, 2-mm gap force and load to failure, was measured under a constant rate of distraction. The stiffness of tendon repair was calculated and the method of repair failure was analyzed. Results: The CLC-IHM group exhibited a statistically significant greater resistance to gapping, a statistically significant higher load to 2-mm gapping (62.0 N), and load to failure (99.7 N) than the DGL-IHM group (37.1 N and 75.1 N, respectively). Ninety percent of CLC-IHM failures were a result of knot failure whereas 30 % of the DGL-IHM group exhibited knot failure. Conclusions: This study demonstrates that the CLC-IHM flexor tendon repair method better resists gapping and has a greater tensile strength compared to the experimental DGL-IHM method. The authors believe that while the DGL-IHM provides double the number of sutures at thePurpose: This study was conducted to compare the in vitro biomechanical properties of tensile strength and gap resistance of a double grasping loop (DGL) flexor tendon repair with the established four-strand cross-locked cruciate (CLC) flexor tendon repair, both with an interlocking horizontal mattress (IHM) epitendinous suture. The hypothesis is that the DGL-IHM method which utilizes two looped core sutures, grasping and locking loops, and a single intralesional knot will have greater strength and increased gap resistance than the CLC-IHM method. Methods: Forty porcine tendons were evenly assigned to either the DGL-IHM or CLC-IHM group. The tendon repair strength, 2-mm gap force and load to failure, was measured under a constant rate of distraction. The stiffness of tendon repair was calculated and the method of repair failure was analyzed. Results: The CLC-IHM group exhibited a statistically significant greater resistance to gapping, a statistically significant higher load to 2-mm gapping (62.0 N), and load to failure (99.7 N) than the DGL-IHM group (37.1 N and 75.1 N, respectively). Ninety percent of CLC-IHM failures were a result of knot failure whereas 30 % of the DGL-IHM group exhibited knot failure. Conclusions: This study demonstrates that the CLC-IHM flexor tendon repair method better resists gapping and has a greater tensile strength compared to the experimental DGL-IHM method. The authors believe that while the DGL-IHM provides double the number of sutures at the repair site per needle pass, this configuration does not adequately secure the loop suture to the tendon, resulting in a high percentage of suture pullout and inability to tolerate loads as high as those of the CLC-IHM group. … (more)
- Is Part Of:
- Hand. Volume 10:Number 1(2015)
- Journal:
- Hand
- Issue:
- Volume 10:Number 1(2015)
- Issue Display:
- Volume 10, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2015-0010-0001-0000
- Page Start:
- 16
- Page End:
- 22
- Publication Date:
- 2015-03
- Subjects:
- Biomechanical study -- Flexor tendon repair
Hand -- Surgery -- Periodicals
Hand -- Surgery
Periodicals
617.57005 - Journal URLs:
- http://www.springerlink.com/content/119980/ ↗
http://journals.sagepub.com/toc/HAN/current ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11552-014-9728-5 ↗
- Languages:
- English
- ISSNs:
- 1558-9447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4241.550050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7060.xml