Laboratory assessment of the quality of adult and neonatal red cell concentrates manufactured from whole blood, exchange transfusion or intrauterine transfusion red cell units. Issue 5 (17th May 2018)
- Record Type:
- Journal Article
- Title:
- Laboratory assessment of the quality of adult and neonatal red cell concentrates manufactured from whole blood, exchange transfusion or intrauterine transfusion red cell units. Issue 5 (17th May 2018)
- Main Title:
- Laboratory assessment of the quality of adult and neonatal red cell concentrates manufactured from whole blood, exchange transfusion or intrauterine transfusion red cell units
- Authors:
- Meli, A.
New, H.
McAndrew, M.
Wiltshire, M.
Cardigan, R. - Abstract:
- Abstract : Background: We evaluated the quality of red cell components in additive solution over 42 days of storage when re‐manufactured from neonatal exchange transfusion (ExTx) or intrauterine transfusion (IUT) units on day 7 for issue to adults, neonates or infants. Materials and methods: Red cell concentrates (RCC) manufactured from WB were compared to RCC re‐manufactured from ExTx or IUT on day 7, and red cell splits (RCS) manufactured from WB were compared to RCS re‐manufactured from ExTx or IUT on day 7. All components were stored at 2–6°C and tested throughout storage until day 42 for in vitro parameters of red cell quality. One RCS manufactured from each of WB, ExTx or IUT, was irradiated on day 14 and tested on day 28 along with a non‐irradiated RCS from the same unit. Results: All the re‐manufactured arms had no worse haemolysis, red cell microvesicle (RCMV) release or ATP over storage compared to controls. All arms complied with the 0·8% haemolysis UK specification, except for re‐manufactured RCS from the IUT arm irradiated on day 14 and tested on day 28. Re‐manufactured units had significantly decreased potassium levels compared to control over storage ( P < 0·001 all). Conclusion: RCC or RCS re‐manufactured from ExTx or IUT units on day 7 are suitable for transfusion up to the standard day 35 of storage. Re‐manufactured RCS from ExTx units (but not IUT), may be irradiated up to day 14 and stored for 14 days post‐irradiation.
- Is Part Of:
- Vox sanguinis. Volume 113:Issue 5(2018)
- Journal:
- Vox sanguinis
- Issue:
- Volume 113:Issue 5(2018)
- Issue Display:
- Volume 113, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 113
- Issue:
- 5
- Issue Sort Value:
- 2018-0113-0005-0000
- Page Start:
- 412
- Page End:
- 420
- Publication Date:
- 2018-05-17
- Subjects:
- exchange transfusion -- intrauterine transfusion -- irradiation -- red cell concentrates -- red cell splits -- top‐up transfusions
Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12662 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: