Reference intervals for plasma cystatin C and plasma creatinine in adults using methods traceable to international calibrators and reference methods. Issue 6 (24th March 2018)
- Record Type:
- Journal Article
- Title:
- Reference intervals for plasma cystatin C and plasma creatinine in adults using methods traceable to international calibrators and reference methods. Issue 6 (24th March 2018)
- Main Title:
- Reference intervals for plasma cystatin C and plasma creatinine in adults using methods traceable to international calibrators and reference methods
- Authors:
- Erlandsen, Erland Jørn
Randers, Else - Abstract:
- Abstract : Introduction: The aim of this study was to establish reference intervals for plasma cystatin C and creatinine in adults using the Gentians cystatin C method traceable to the international calibrator standard ERM‐DA471/IFCC and a creatinine method traceable to the IDMS (Isotope Dilution Mass Spectrometry) creatinine reference method. Methods: Blood samples were collected from 304 healthy blood donors (152 men and 152 women between 17 and 66 years old) with 30‐31 men and 30‐31 women in each ten‐year interval. Plasma cystatin C was analyzed using the Gentian Cystatin C assay on a Roche cobas c702 analyzer, and plasma creatinine was analyzed using the CREA Plus assay on the Roche Modular P analyzer. Results: The nonparametric reference intervals for plasma cystatin C were 0.58‐1.00 mg/L in women (median 0.78 mg/L, range 0.56‐1.06 mg/L) and 0.62‐1.04 mg/L in men (median 0.79 mg/L, range 0.61‐1.07 mg/L). The Mann‐Whitney U test revealed no gender‐related difference in plasma cystatin C ( P = .21). A common reference interval in women and men was calculated to be 0.61‐1.01 mg/L (median 0.79 mg/L, range 0.56‐1.07 mg/L). The nonparametric reference interval for plasma creatinine was 52‐89 μmol/L in women (median 69 μmol/L, range 52‐92 μmol/L) and 61‐108 μmol/L in men (median 86 μmol/L, range 56‐118 μmol/L). The Mann‐Whitney U test revealed a gender‐related difference in plasma creatinine ( P < .0001). Conclusion: In conclusion, we have established reference intervals forAbstract : Introduction: The aim of this study was to establish reference intervals for plasma cystatin C and creatinine in adults using the Gentians cystatin C method traceable to the international calibrator standard ERM‐DA471/IFCC and a creatinine method traceable to the IDMS (Isotope Dilution Mass Spectrometry) creatinine reference method. Methods: Blood samples were collected from 304 healthy blood donors (152 men and 152 women between 17 and 66 years old) with 30‐31 men and 30‐31 women in each ten‐year interval. Plasma cystatin C was analyzed using the Gentian Cystatin C assay on a Roche cobas c702 analyzer, and plasma creatinine was analyzed using the CREA Plus assay on the Roche Modular P analyzer. Results: The nonparametric reference intervals for plasma cystatin C were 0.58‐1.00 mg/L in women (median 0.78 mg/L, range 0.56‐1.06 mg/L) and 0.62‐1.04 mg/L in men (median 0.79 mg/L, range 0.61‐1.07 mg/L). The Mann‐Whitney U test revealed no gender‐related difference in plasma cystatin C ( P = .21). A common reference interval in women and men was calculated to be 0.61‐1.01 mg/L (median 0.79 mg/L, range 0.56‐1.07 mg/L). The nonparametric reference interval for plasma creatinine was 52‐89 μmol/L in women (median 69 μmol/L, range 52‐92 μmol/L) and 61‐108 μmol/L in men (median 86 μmol/L, range 56‐118 μmol/L). The Mann‐Whitney U test revealed a gender‐related difference in plasma creatinine ( P < .0001). Conclusion: In conclusion, we have established reference intervals for plasma cystatin C and creatinine in adults using methods traceable to international standards. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 32:Issue 6(2018)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 32:Issue 6(2018)
- Issue Display:
- Volume 32, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 6
- Issue Sort Value:
- 2018-0032-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-03-24
- Subjects:
- creatinine -- cystatin C -- glomerular filtration rate -- kidney function -- reference values
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22433 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7048.xml