Clinical Adaptation of the "Tibiofibular Line" for Intraoperative Evaluation of Open Syndesmosis Reduction Accuracy: A Cadaveric Study. (November 2016)
- Record Type:
- Journal Article
- Title:
- Clinical Adaptation of the "Tibiofibular Line" for Intraoperative Evaluation of Open Syndesmosis Reduction Accuracy: A Cadaveric Study. (November 2016)
- Main Title:
- Clinical Adaptation of the "Tibiofibular Line" for Intraoperative Evaluation of Open Syndesmosis Reduction Accuracy
- Authors:
- Reb, Christopher W.
Hyer, Christopher F.
Collins, Christy L.
Fidler, Corey M.
Watson, B. Collier
Berlet, Gregory C. - Abstract:
- Background: The "tibiofibular line" is a new axial computed tomography parameter for assessing syndesmosis reduction, which references the flat anterolateral surface of the fibula and anterolateral tibial tubercle. These same bony landmarks are easily visualized via a lateral approach to the fibula. This cadaveric study assessed the practical aspects of measuring the tibiofibular line intraoperatively. Methods: Three observers simulated the tibiofibular line using operative rulers in 3 measurement series utilizing 10 cadaveric specimens: intact syndesmosis, syndesmosis reduction, and fixation after application of lateral plate and screws to the fibula, and post syndesmosis reduction and fixation without plate and screws. Results: The majority (78%) of clinical tibiofibular line measurements were within the "normal" range (0-2 mm). However, there was a general trend toward malreduction (>2 mm) across measurement series. Intraobserver variability ranged from poor to excellent (intraclass correlation range, 0.12-0.85, Fleiss kappa range, 0.19-0.40) and interobserver reliability was only generally in the fair range (intraclass correlation range, 0.49-0.61; Fleiss kappa range, 0.19-0.40). Conclusion: Taken as a whole, these findings found that the technique was feasible but clearly indicated that further refinement of this protocol, including the use of computed tomography, would be needed to determine if better control of confounding variables would reveal better observerBackground: The "tibiofibular line" is a new axial computed tomography parameter for assessing syndesmosis reduction, which references the flat anterolateral surface of the fibula and anterolateral tibial tubercle. These same bony landmarks are easily visualized via a lateral approach to the fibula. This cadaveric study assessed the practical aspects of measuring the tibiofibular line intraoperatively. Methods: Three observers simulated the tibiofibular line using operative rulers in 3 measurement series utilizing 10 cadaveric specimens: intact syndesmosis, syndesmosis reduction, and fixation after application of lateral plate and screws to the fibula, and post syndesmosis reduction and fixation without plate and screws. Results: The majority (78%) of clinical tibiofibular line measurements were within the "normal" range (0-2 mm). However, there was a general trend toward malreduction (>2 mm) across measurement series. Intraobserver variability ranged from poor to excellent (intraclass correlation range, 0.12-0.85, Fleiss kappa range, 0.19-0.40) and interobserver reliability was only generally in the fair range (intraclass correlation range, 0.49-0.61; Fleiss kappa range, 0.19-0.40). Conclusion: Taken as a whole, these findings found that the technique was feasible but clearly indicated that further refinement of this protocol, including the use of computed tomography, would be needed to determine if better control of confounding variables would reveal better observer reliability. Clinical Relevance: The CT-based TFL technique for syndesmosis reduction assessment could not reliably be translated into an intraoperative open technique because of the confounding effects of subjectivity and operator error. … (more)
- Is Part Of:
- Foot & ankle international. Volume 37:Number 11(2016:Nov.)
- Journal:
- Foot & ankle international
- Issue:
- Volume 37:Number 11(2016:Nov.)
- Issue Display:
- Volume 37, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 11
- Issue Sort Value:
- 2016-0037-0011-0000
- Page Start:
- 1243
- Page End:
- 1248
- Publication Date:
- 2016-11
- Subjects:
- ankle sprain -- computed tomography -- trauma -- technique
Foot -- Abnormalities -- Periodicals
Ankle -- Abnormalities -- Periodicals
Orthopedics -- Periodicals
617.585 - Journal URLs:
- http://fai.sagepub.com/ ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00041550-000000000-00000 ↗
http://www.sagepublications.com/ ↗
http://207.158.206.46/medical/FAI_body.htm ↗
http://www.datatrace.com/medical/FAI_online.htm ↗ - DOI:
- 10.1177/1071100716660822 ↗
- Languages:
- English
- ISSNs:
- 1071-1007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7053.xml