Predictors of a high defibrillation threshold test during routine ICD implantation. Issue 3 (4th May 2018)
- Record Type:
- Journal Article
- Title:
- Predictors of a high defibrillation threshold test during routine ICD implantation. Issue 3 (4th May 2018)
- Main Title:
- Predictors of a high defibrillation threshold test during routine ICD implantation
- Authors:
- Al-Atia, B.
Vandenberk, B.
Vörös, G.
Garweg, C.
Ector, J.
Willems, R. - Abstract:
- Abstract: Background: There is growing evidence that routine defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation is not necessary. However a small group of patients might be at risk if no DFT testing is performed. Methods: Patients with a new pectoral ICD implantation in our hospital between 2006 and 2014 were included in a retrospective registry. A clinical high DFT was defined as a safety margin <10 J of the maximal device output. Logistic regression for prediction of high DFT was performed using patient characteristics, clinical, echocardiographic and device-related parameters. Results: DFT testing was performed in 788/864 (91.2%) procedures. In 76 (8.8%) patients no DFT testing was performed mainly due to atrial fibrillation, intra-cardiac thrombus, hemodynamic instability or logistical reasons. A high DFT was present in 44 (5.6%) patients. A QRS duration ≥150 ms, a low left ventricular ejection fraction (LVEF ≤25%), a severely dilated left ventricle ≥60 mm and right sided pre-pectoral implantations were univariate predictors of a high DFT. Independent predictors of a high DFT were a LVEF ≤25% (HR 2.195, 95%CI 1.085–4.443) and right sided pre-pectoral implantations (HR 3.135, 95% CI 1.186–8.287). Conclusions: A high DFT is still present in about 5% of patients and is more frequent in patients with a severely dilated left ventricle, a very low LVEF, right sided pre-pectoral implantation and wider QRS duration. It mightAbstract: Background: There is growing evidence that routine defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation is not necessary. However a small group of patients might be at risk if no DFT testing is performed. Methods: Patients with a new pectoral ICD implantation in our hospital between 2006 and 2014 were included in a retrospective registry. A clinical high DFT was defined as a safety margin <10 J of the maximal device output. Logistic regression for prediction of high DFT was performed using patient characteristics, clinical, echocardiographic and device-related parameters. Results: DFT testing was performed in 788/864 (91.2%) procedures. In 76 (8.8%) patients no DFT testing was performed mainly due to atrial fibrillation, intra-cardiac thrombus, hemodynamic instability or logistical reasons. A high DFT was present in 44 (5.6%) patients. A QRS duration ≥150 ms, a low left ventricular ejection fraction (LVEF ≤25%), a severely dilated left ventricle ≥60 mm and right sided pre-pectoral implantations were univariate predictors of a high DFT. Independent predictors of a high DFT were a LVEF ≤25% (HR 2.195, 95%CI 1.085–4.443) and right sided pre-pectoral implantations (HR 3.135, 95% CI 1.186–8.287). Conclusions: A high DFT is still present in about 5% of patients and is more frequent in patients with a severely dilated left ventricle, a very low LVEF, right sided pre-pectoral implantation and wider QRS duration. It might be clinically important to continue DFT testing in these high risk patients. … (more)
- Is Part Of:
- Acta cardiologica. Volume 73:Issue 3(2018)
- Journal:
- Acta cardiologica
- Issue:
- Volume 73:Issue 3(2018)
- Issue Display:
- Volume 73, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 73
- Issue:
- 3
- Issue Sort Value:
- 2018-0073-0003-0000
- Page Start:
- 267
- Page End:
- 273
- Publication Date:
- 2018-05-04
- Subjects:
- Implantable cardioverter defibrillator (ICD) -- defibrillation threshold (DFT) -- ventricular fibrillation (VF)
Cardiology -- Periodicals
Cardiology
Cardiologie -- Périodiques
Cardiology
Cardiologie
Periodicals
Periodicals
616.12005 - Journal URLs:
- http://www.tandfonline.com/ ↗
http://www.tandfonline.com/toc/tacd20/current?nav=tocList ↗
http://www.actacardiologica.be/ ↗
http://ejournals.ebsco.com/direct.asp?JournalID=114963 ↗ - DOI:
- 10.1080/00015385.2017.1371455 ↗
- Languages:
- English
- ISSNs:
- 0001-5385
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7048.xml