Applicability and procedural success rate of bioresorbable vascular scaffolds for percutaneous coronary intervention in an all-comer cohort of 383 consecutive patients. Issue 4 (4th July 2017)
- Record Type:
- Journal Article
- Title:
- Applicability and procedural success rate of bioresorbable vascular scaffolds for percutaneous coronary intervention in an all-comer cohort of 383 consecutive patients. Issue 4 (4th July 2017)
- Main Title:
- Applicability and procedural success rate of bioresorbable vascular scaffolds for percutaneous coronary intervention in an all-comer cohort of 383 consecutive patients
- Authors:
- Schlundt, Christian
Achenbach, Stephan
Felten, Fabiola
Roether, Jens
Marwan, Mohamed
Nef, Holger
Ludwig, Josef
Tröbs, Monique - Abstract:
- Abstract : Objectives The purpose of this study was to determine applicability and procedural success of bioresorbable vascular scaffolds (BVS) for percutaneous coronary intervention (PCI) in an all-comer cohort. Background BVS use in bifurcations and severely calcified lesions is not recommended, and a relatively large crossing profile may cause limitations. It is has never been studied how widely BVS can be applied in all-comer cohorts. Methods In 383 consecutive patients (acute coronary syndrome: 124, stable coronary disease 259), a BVS (Absorb) was used as first-line device unless any of the following contraindications were present: bifurcation with side branch >2.0 mm, reference diameter <2.5 mm or >4.0 mm, required device length <12 mm, in-stent stenosis, or contraindications to 6 months of DAPT. Patients and lesions were evaluated regarding suitability for BVS treatment, procedural success (successful BVS placement and residual stenosis <30%), and outcome. Results Of 588 lesions, 303 (52%) were unsuitable for BVS placement due to presence of a bifurcation (30% of unsuitable lesions), reference diameter >4.0 mm (13%) or <2.5 mm (12%), contraindication to 6 months DAPT (13%), in-stent stenosis (14%), and desired device length <12 mm (4%). If BVS use was attempted, procedural success with a scaffold was 95% (271/285). Crossing failure occurred in 14 cases (5%), affected lesions were significantly more calcified. After a mean follow-up period of 259 days,Abstract : Objectives The purpose of this study was to determine applicability and procedural success of bioresorbable vascular scaffolds (BVS) for percutaneous coronary intervention (PCI) in an all-comer cohort. Background BVS use in bifurcations and severely calcified lesions is not recommended, and a relatively large crossing profile may cause limitations. It is has never been studied how widely BVS can be applied in all-comer cohorts. Methods In 383 consecutive patients (acute coronary syndrome: 124, stable coronary disease 259), a BVS (Absorb) was used as first-line device unless any of the following contraindications were present: bifurcation with side branch >2.0 mm, reference diameter <2.5 mm or >4.0 mm, required device length <12 mm, in-stent stenosis, or contraindications to 6 months of DAPT. Patients and lesions were evaluated regarding suitability for BVS treatment, procedural success (successful BVS placement and residual stenosis <30%), and outcome. Results Of 588 lesions, 303 (52%) were unsuitable for BVS placement due to presence of a bifurcation (30% of unsuitable lesions), reference diameter >4.0 mm (13%) or <2.5 mm (12%), contraindication to 6 months DAPT (13%), in-stent stenosis (14%), and desired device length <12 mm (4%). If BVS use was attempted, procedural success with a scaffold was 95% (271/285). Crossing failure occurred in 14 cases (5%), affected lesions were significantly more calcified. After a mean follow-up period of 259 days, definite/probable scaffold thrombosis occurred in 1.1% of patients. Conclusions Approximately one-half of lesions in an all-comer population can successfully be treated with BVS. Crossing failure is rare. … (more)
- Is Part Of:
- Acta cardiologica. Volume 72:Issue 4(2017)
- Journal:
- Acta cardiologica
- Issue:
- Volume 72:Issue 4(2017)
- Issue Display:
- Volume 72, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 72
- Issue:
- 4
- Issue Sort Value:
- 2017-0072-0004-0000
- Page Start:
- 425
- Page End:
- 432
- Publication Date:
- 2017-07-04
- Subjects:
- Intervention -- failure -- stent -- absorb -- scaffold
Cardiology -- Periodicals
Cardiology
Cardiologie -- Périodiques
Cardiology
Cardiologie
Periodicals
Periodicals
616.12005 - Journal URLs:
- http://www.tandfonline.com/ ↗
http://www.tandfonline.com/toc/tacd20/current?nav=tocList ↗
http://www.actacardiologica.be/ ↗
http://ejournals.ebsco.com/direct.asp?JournalID=114963 ↗ - DOI:
- 10.1080/00015385.2017.1307659 ↗
- Languages:
- English
- ISSNs:
- 0001-5385
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7058.xml