Effects of transcutaneous acupoint electrical stimulation combined with low-dose sufentanil pretreatment on the incidence and severity of etomidate-induced myoclonus: A randomized controlled trial. Issue 23 (June 2018)
- Record Type:
- Journal Article
- Title:
- Effects of transcutaneous acupoint electrical stimulation combined with low-dose sufentanil pretreatment on the incidence and severity of etomidate-induced myoclonus: A randomized controlled trial. Issue 23 (June 2018)
- Main Title:
- Effects of transcutaneous acupoint electrical stimulation combined with low-dose sufentanil pretreatment on the incidence and severity of etomidate-induced myoclonus
- Authors:
- Lv, Ya
He, Haijuan
Xie, Junjie
Jin, WenJun
Shou, CanJi
Pan, Yuanyuan
Wang, Leilei
Mo, Yunchang
Dai, Qinxue
Geng, Wujun
Wang, Junlu - Other Names:
- Gharaei. Helen section editor.
- Abstract:
- Abstract: Background: Myoclonus is an undesirable phenomenon that occurs after induction of general anesthesia using etomidate. Opioids such as sufentanil are considered effective pretreatment drugs for myoclonus inhibition, although high doses are required. Transcutaneous acupoint electrical stimulation (TAES), a noninvasive technique involving electrical stimulation of the skin at the acupuncture points, exhibits analgesic effects, promotes anesthetic effects, decreases the dose of anesthetic drugs, and increases endogenous opioid peptide levels. In the present study, we investigated the effects of TAES combined with low-dose sufentanil pretreatment on the incidence and severity of etomidate-induced myoclonus in patients undergoing elective hysteroscopy. Methods: In a double-blind manner, 172 patients (American Society of Anesthesiologists class I–II; age, 20–55 years) scheduled to undergo elective hysteroscopy were randomized into the following groups (n = 43 each): control (false TAES followed by saline injection after 30 min), TAES (TAES followed by saline injection after 30 minutes), sufentanil [false TAES followed by low-dose sufentanil (0.1 μg/kg) injection after 30 minutes], and sufentanil plus TAES (TAES followed by low-dose sufentanil injection after 30 minutes). In all groups, general anesthesia was induced by etomidate 0.3 mg/kg after sufentanil or saline injection. The incidence and severity of myoclonus were assessed for 2 minutes after etomidateAbstract: Background: Myoclonus is an undesirable phenomenon that occurs after induction of general anesthesia using etomidate. Opioids such as sufentanil are considered effective pretreatment drugs for myoclonus inhibition, although high doses are required. Transcutaneous acupoint electrical stimulation (TAES), a noninvasive technique involving electrical stimulation of the skin at the acupuncture points, exhibits analgesic effects, promotes anesthetic effects, decreases the dose of anesthetic drugs, and increases endogenous opioid peptide levels. In the present study, we investigated the effects of TAES combined with low-dose sufentanil pretreatment on the incidence and severity of etomidate-induced myoclonus in patients undergoing elective hysteroscopy. Methods: In a double-blind manner, 172 patients (American Society of Anesthesiologists class I–II; age, 20–55 years) scheduled to undergo elective hysteroscopy were randomized into the following groups (n = 43 each): control (false TAES followed by saline injection after 30 min), TAES (TAES followed by saline injection after 30 minutes), sufentanil [false TAES followed by low-dose sufentanil (0.1 μg/kg) injection after 30 minutes], and sufentanil plus TAES (TAES followed by low-dose sufentanil injection after 30 minutes). In all groups, general anesthesia was induced by etomidate 0.3 mg/kg after sufentanil or saline injection. The incidence and severity of myoclonus were assessed for 2 minutes after etomidate administration. The visual analogue scale (VAS) scores for pain at 1 hour after surgery were recorded. The heart rate (HR), mean arterial pressure (MAP), and peripheral capillary oxygen saturation (SPO2 ) were recorded before premedication, after etomidate injection, after uterus expansion, and after recovery from anesthesia. Results: The incidence of myoclonus was highest in the control group (88.3%), followed by TAES (74.4%), sufentanil (60.4%), and TAES plus sufentanil (48.8%) groups. Thus, the incidence was significantly higher in the control and TAES groups than in the sufentanil and TAES plus sufentanil groups. Grade 3 myoclonus occurred in 30.2%, 9.3%, 11.6%, and 9.3% patients in the control, TAES, sufentanil, and TAES plus sufentanil groups, respectively, with significant differences between the control group and the other 3 groups. Furthermore, the postoperative VAS scores for pain were significantly lower in the TAES, sufentanil, and TAES plus sufentanil groups compared with those in the control group. There were no significant differences in any other parameters among groups. Conclusion: Our results suggest that TAES combined with low-dose opioids such as sufentanil can decrease the incidence and severity of etomidate-induced myoclonus. … (more)
- Is Part Of:
- Medicine. Volume 97:Issue 23(2018)
- Journal:
- Medicine
- Issue:
- Volume 97:Issue 23(2018)
- Issue Display:
- Volume 97, Issue 23 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 23
- Issue Sort Value:
- 2018-0097-0023-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-06
- Subjects:
- etomidate -- hysteroscopy -- myoclonus -- sufentanil -- transcutaneous acupoint electrical stimulation
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000010969 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7046.xml