Three-Dimensional Modeling for Crohn's Fistula-in-Ano: A Novel, Interactive Approach. Issue 5 (May 2018)
- Record Type:
- Journal Article
- Title:
- Three-Dimensional Modeling for Crohn's Fistula-in-Ano: A Novel, Interactive Approach. Issue 5 (May 2018)
- Main Title:
- Three-Dimensional Modeling for Crohn's Fistula-in-Ano
- Authors:
- Lam, David
Yong, Eric
D'Souza, Basil
Woods, Rodney - Abstract:
- Abstract : BACKGROUND: Pelvic MRI allows for clear delineation of anatomy in Crohn's fistula-in-ano, although its interpretation is often difficult for nonradiologists. OBJECTIVE: The aim was to develop a 3-dimensional model where fistula tracts and their relationship to the sphincter complex can be accurately defined, which can then be rotated in multiple axes by the surgeon. DESIGN: A 3-dimensional model was created based on MRI images. An additional 3-dimensional T2-weighted sequence was added to the existing MRI protocol to obtain high-resolution images. Segmentation of the fistula tract and volume rendering of the segmented tract were performed to create the final model. SETTINGS: This was a single-center study conducted in Victoria, Australia. PATIENTS: All of the patients who had pelvic MRI for fistulating Crohn's disease between March 2016 and March 2017 had the additional MRI sequence. INTERVENTIONS: Postprocessing of MRI images was performed by a single radiologist. RESULTS: Total acquisition time for MRI images was extended to 31 minutes compared with the standard 2-dimensional protocol lasting 25 minutes. Additional postprocessing time used to create the model was ≈15 minutes. Two clinical vignettes using this model are presented and compared with conventional 2-dimensional MRI images to highlight the use of the 3-dimensional modeling technique. LIMITATIONS: This technique involves a semiautomatic process of fistula tract segmentation that requires radiologistAbstract : BACKGROUND: Pelvic MRI allows for clear delineation of anatomy in Crohn's fistula-in-ano, although its interpretation is often difficult for nonradiologists. OBJECTIVE: The aim was to develop a 3-dimensional model where fistula tracts and their relationship to the sphincter complex can be accurately defined, which can then be rotated in multiple axes by the surgeon. DESIGN: A 3-dimensional model was created based on MRI images. An additional 3-dimensional T2-weighted sequence was added to the existing MRI protocol to obtain high-resolution images. Segmentation of the fistula tract and volume rendering of the segmented tract were performed to create the final model. SETTINGS: This was a single-center study conducted in Victoria, Australia. PATIENTS: All of the patients who had pelvic MRI for fistulating Crohn's disease between March 2016 and March 2017 had the additional MRI sequence. INTERVENTIONS: Postprocessing of MRI images was performed by a single radiologist. RESULTS: Total acquisition time for MRI images was extended to 31 minutes compared with the standard 2-dimensional protocol lasting 25 minutes. Additional postprocessing time used to create the model was ≈15 minutes. Two clinical vignettes using this model are presented and compared with conventional 2-dimensional MRI images to highlight the use of the 3-dimensional modeling technique. LIMITATIONS: This technique involves a semiautomatic process of fistula tract segmentation that requires radiologist expertise and additional postprocessing time. CONCLUSIONS: This 3-dimensional modeling technique enables accurate identification of tracts in Crohn's fistula-in-ano and improves spatial orientation for the surgeon. The model has the potential to be an invaluable preoperative tool to guide operative decision-making, as well as enabling the assessment of response to medical or surgical therapy. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Diseases of the colon & rectum. Volume 61:Issue 5(2018)
- Journal:
- Diseases of the colon & rectum
- Issue:
- Volume 61:Issue 5(2018)
- Issue Display:
- Volume 61, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 61
- Issue:
- 5
- Issue Sort Value:
- 2018-0061-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-05
- Subjects:
- Crohn's disease -- Magnetic resonance imaging -- Rectal fistula
Colon (Anatomy) -- Diseases -- Periodicals
Rectum -- Diseases -- Periodicals
Colonic Diseases -- Periodicals
Colorectal Surgery -- Periodicals
616.34 - Journal URLs:
- http://journals.lww.com/dcrjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/DCR.0000000000001084 ↗
- Languages:
- English
- ISSNs:
- 0012-3706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3598.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7037.xml