Early Detection of Infusion Set Failure During Insulin Pump Therapy in Type 1 Diabetes. (November 2016)
- Record Type:
- Journal Article
- Title:
- Early Detection of Infusion Set Failure During Insulin Pump Therapy in Type 1 Diabetes. (November 2016)
- Main Title:
- Early Detection of Infusion Set Failure During Insulin Pump Therapy in Type 1 Diabetes
- Authors:
- Cescon, Marzia
DeSalvo, Daniel J.
Ly, Trang T.
Maahs, David M.
Messer, Laurel H.
Buckingham, Bruce A.
Doyle, Francis J.
Dassau, Eyal - Abstract:
- Background: Insulin infusion set failure resulting in prolonged hyperglycemia or diabetic ketoacidosis can occur with pump therapy in type 1 diabetes. Set failures are frequently characterized by variable and unpredictable patterns of increasing glucose values despite increased insulin infusion. Early detection may minimize the risk of prolonged hyperglycemia, an important consideration for automated insulin delivery and closed-loop applications. Methods: A novel algorithm designed to alert the patient to the onset of infusion set failure was developed based upon continuous glucose sensor values and insulin delivered from an insulin pump. The method was calibrated on 12 weeks of infusion set wear without failures recorded by 4 patients in ambulatory conditions and prospectively validated on 18 weeks of infusion set wear with and without failures belonging to 9 other subjects in ambulatory conditions. Results: The algorithm, evaluated retrospectively, identified a failure 2.52 ± 1.91 days ahead of the actual event as recorded by the clinical team, corresponding to 50% sensitivity, 66% specificity and 55% accuracy. If set failure alarms had been activated in real time, the average time >180 mg/dl would be reduced from 82.7 ± 40.9 hours/week/subject (without alarm) to 58.8 ± 31.1 hours/week/subject (with alarm), corresponding to a potential 29% reduction in time spent >180mg/dl. Conclusion: The proposed method for early detection of infusion set failure based on glucose sensorBackground: Insulin infusion set failure resulting in prolonged hyperglycemia or diabetic ketoacidosis can occur with pump therapy in type 1 diabetes. Set failures are frequently characterized by variable and unpredictable patterns of increasing glucose values despite increased insulin infusion. Early detection may minimize the risk of prolonged hyperglycemia, an important consideration for automated insulin delivery and closed-loop applications. Methods: A novel algorithm designed to alert the patient to the onset of infusion set failure was developed based upon continuous glucose sensor values and insulin delivered from an insulin pump. The method was calibrated on 12 weeks of infusion set wear without failures recorded by 4 patients in ambulatory conditions and prospectively validated on 18 weeks of infusion set wear with and without failures belonging to 9 other subjects in ambulatory conditions. Results: The algorithm, evaluated retrospectively, identified a failure 2.52 ± 1.91 days ahead of the actual event as recorded by the clinical team, corresponding to 50% sensitivity, 66% specificity and 55% accuracy. If set failure alarms had been activated in real time, the average time >180 mg/dl would be reduced from 82.7 ± 40.9 hours/week/subject (without alarm) to 58.8 ± 31.1 hours/week/subject (with alarm), corresponding to a potential 29% reduction in time spent >180mg/dl. Conclusion: The proposed method for early detection of infusion set failure based on glucose sensor and insulin data demonstrated favorable results on retrospective data and may be implemented as an additional safeguard in a future fully automated closed-loop system. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 10:Number 6(2016:Nov.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 10:Number 6(2016:Nov.)
- Issue Display:
- Volume 10, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 6
- Issue Sort Value:
- 2016-0010-0006-0000
- Page Start:
- 1268
- Page End:
- 1276
- Publication Date:
- 2016-11
- Subjects:
- infusion set failures -- artificial pancreas
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296816663962 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7044.xml