Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol. (May 2016)
- Record Type:
- Journal Article
- Title:
- Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol. (May 2016)
- Main Title:
- Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol
- Authors:
- Klonoff, David C.
Lias, Courtney
Beck, Stayce
Parkes, Joan Lee
Kovatchev, Boris
Vigersky, Robert A.
Arreaza-Rubin, Guillermo
Burk, Robert D.
Kowalski, Aaron
Little, Randie
Nichols, James
Petersen, Matt
Rawlings, Kelly
Sacks, David B.
Sampson, Eric
Scott, Steve
Seley, Jane Jeffrie
Slingerland, Robbert
Vesper, Hubert W. - Abstract:
- Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSsBackground: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 10:Number 3(2016:May)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 10:Number 3(2016:May)
- Issue Display:
- Volume 10, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 3
- Issue Sort Value:
- 2016-0010-0003-0000
- Page Start:
- 697
- Page End:
- 707
- Publication Date:
- 2016-05
- Subjects:
- accuracy -- blood glucose monitor -- FDA -- meter -- protocol -- surveillance
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296815614587 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7034.xml