Preparation of a magnetic multiwalled carbon nanotube@polydopamine/zeolitic imidazolate framework-8 composite for magnetic solid-phase extraction of triazole fungicides from environmental water samples. Issue 45 (16th July 2018)
- Record Type:
- Journal Article
- Title:
- Preparation of a magnetic multiwalled carbon nanotube@polydopamine/zeolitic imidazolate framework-8 composite for magnetic solid-phase extraction of triazole fungicides from environmental water samples. Issue 45 (16th July 2018)
- Main Title:
- Preparation of a magnetic multiwalled carbon nanotube@polydopamine/zeolitic imidazolate framework-8 composite for magnetic solid-phase extraction of triazole fungicides from environmental water samples
- Authors:
- Huang, Xiaodong
Liu, Yanan
Liu, Guangyang
Li, Lingyun
Xu, Xiaomin
Zheng, Shuning
Xu, Donghui
Gao, Haixiang - Abstract:
- Abstract : A magnetic ZIF-8 composite was prepared based on Fe3 O4 /MWCNT@PDA and used as an adsorbent for MSPE of triazoles from environmental water samples. Abstract : A novel magnetic zinc-based zeolitic imidazolate framework (MMP/ZIF-8) has been prepared using a magnetic multiwalled carbon nanotube@polydopamine nanocomposite as the magnetic core and support. It was then used as an adsorbent for magnetic solid-phase extraction of triazole fungicides from environmental water samples. Successful synthesis of MMP/ZIF-8 was confirmed by material characterization, and the results showed that the synthetic composite has a high Brunauer–Emmett–Teller surface area (141.56 m 2 g −1 ), large total pore volume (0.636 mL g −1 ), and high superparamagnetism with a saturation magnetization of 44.1 emu g −1 . To evaluate the extraction performance of MMP/ZIF-8, the main parameters that affect the extraction efficiency were optimized. Under the optimal conditions, the developed method shows good linearity ( R 2 ≥ 0.9915) in the concentration range 1–400 μg L −1 . Low limits of detection (0.08–0.27 μg L −1, signal/noise = 3 : 1) and good precision (intraday relative standard deviation ≤ 7.73%, interday relative standard deviation ≤ 9.65%) are also achieved. The developed method was applied for analysis of triazole fungicides in environmental water samples.
- Is Part Of:
- RSC advances. Volume 8:Issue 45(2018)
- Journal:
- RSC advances
- Issue:
- Volume 8:Issue 45(2018)
- Issue Display:
- Volume 8, Issue 45 (2018)
- Year:
- 2018
- Volume:
- 8
- Issue:
- 45
- Issue Sort Value:
- 2018-0008-0045-0000
- Page Start:
- 25351
- Page End:
- 25360
- Publication Date:
- 2018-07-16
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ra05064c ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7014.xml