Comparative evaluation of topographical data of dental implant surfaces applying optical interferometry and scanning electron microscopy. Issue 8 (August 2017)
- Record Type:
- Journal Article
- Title:
- Comparative evaluation of topographical data of dental implant surfaces applying optical interferometry and scanning electron microscopy. Issue 8 (August 2017)
- Main Title:
- Comparative evaluation of topographical data of dental implant surfaces applying optical interferometry and scanning electron microscopy
- Authors:
- Kournetas, N.
Spintzyk, S.
Schweizer, E.
Sawada, T.
Said, F.
Schmid, P.
Geis-Gerstorfer, J.
Eliades, G.
Rupp, F. - Abstract:
- Highlights: Roughness analyses of marketed dental implant screws was conducted. Stereo-SEM and interferometry exhibited predominant statistical differences. Both methods revealed different ability to discriminate between surfaces. A clinically relevant categorizing approach showed promise for evaluation. Surface analyses of implants require more sophisticated guidelines. Abstract: Objective: Comparability of topographical data of implant surfaces in literature is low and their clinical relevance often equivocal. The aim of this study was to investigate the ability of scanning electron microscopy and optical interferometry to assess statistically similar 3-dimensional roughness parameter results and to evaluate these data based on predefined criteria regarded relevant for a favorable biological response. Methods: Four different commercial dental screw-type implants (NanoTite Certain Prevail, TiUnite Brånemark Mk III, XiVE S Plus and SLA Standard Plus) were analyzed by stereo scanning electron microscopy and white light interferometry. Surface height, spatial and hybrid roughness parameters (Sa, Sz, Ssk, Sku, Sal, Str, Sdr) were assessed from raw and filtered data (Gaussian 50 μm and 5 μm cut-off-filters), respectively. Data were statistically compared by one-way ANOVA and Tukey–Kramer post-hoc test. For a clinically relevant interpretation, a categorizing evaluation approach was used based on predefined threshold criteria for each roughness parameter. Results: The two methodsHighlights: Roughness analyses of marketed dental implant screws was conducted. Stereo-SEM and interferometry exhibited predominant statistical differences. Both methods revealed different ability to discriminate between surfaces. A clinically relevant categorizing approach showed promise for evaluation. Surface analyses of implants require more sophisticated guidelines. Abstract: Objective: Comparability of topographical data of implant surfaces in literature is low and their clinical relevance often equivocal. The aim of this study was to investigate the ability of scanning electron microscopy and optical interferometry to assess statistically similar 3-dimensional roughness parameter results and to evaluate these data based on predefined criteria regarded relevant for a favorable biological response. Methods: Four different commercial dental screw-type implants (NanoTite Certain Prevail, TiUnite Brånemark Mk III, XiVE S Plus and SLA Standard Plus) were analyzed by stereo scanning electron microscopy and white light interferometry. Surface height, spatial and hybrid roughness parameters (Sa, Sz, Ssk, Sku, Sal, Str, Sdr) were assessed from raw and filtered data (Gaussian 50 μm and 5 μm cut-off-filters), respectively. Data were statistically compared by one-way ANOVA and Tukey–Kramer post-hoc test. For a clinically relevant interpretation, a categorizing evaluation approach was used based on predefined threshold criteria for each roughness parameter. Results: The two methods exhibited predominantly statistical differences. Dependent on roughness parameters and filter settings, both methods showed variations in rankings of the implant surfaces and differed in their ability to discriminate the different topographies. Overall, the analyses revealed scale-dependent roughness data. Compared to the pure statistical approach, the categorizing evaluation resulted in much more similarities between the two methods. Significance: This study suggests to reconsider current approaches for the topographical evaluation of implant surfaces and to further seek after proper experimental settings. Furthermore, the specific role of different roughness parameters for the bioresponse has to be studied in detail in order to better define clinically relevant, scale-dependent and parameter-specific thresholds and ranges. … (more)
- Is Part Of:
- Dental materials. Volume 33:Issue 8(2017)
- Journal:
- Dental materials
- Issue:
- Volume 33:Issue 8(2017)
- Issue Display:
- Volume 33, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 8
- Issue Sort Value:
- 2017-0033-0008-0000
- Page Start:
- e317
- Page End:
- e327
- Publication Date:
- 2017-08
- Subjects:
- Stereo-SEM -- Optical interferometry -- Multi-level roughness analysis -- Raw data -- Categorizing surface evaluation
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2017.04.020 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7009.xml