Accuracy of left atrial bipolar voltages obtained by ConfiDENSE multielectrode mapping in patients with persistent atrial fibrillation. (6th April 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy of left atrial bipolar voltages obtained by ConfiDENSE multielectrode mapping in patients with persistent atrial fibrillation. (6th April 2018)
- Main Title:
- Accuracy of left atrial bipolar voltages obtained by ConfiDENSE multielectrode mapping in patients with persistent atrial fibrillation
- Authors:
- Maille, Baptiste
Das, Moloy
Hussein, Ahmed
Shaw, Matthew
Chaturvedi, Vivek
Morgan, Maureen
Ronayne, Christina
Snowdon, Richard L.
Gupta, Dhiraj - Abstract:
- Abstract: Introduction: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. Methods and results: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). Conclusion: Application of the TPI filter toAbstract: Introduction: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. Methods and results: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). Conclusion: Application of the TPI filter to ConfiDENSE maps significantly increases the quality of the voltage data, conserving a reasonable point density, but still overestimates low voltage points as compared to CF‐sensing maps or maps reviewed manually. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 29:Number 6(2018)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 29:Number 6(2018)
- Issue Display:
- Volume 29, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 6
- Issue Sort Value:
- 2018-0029-0006-0000
- Page Start:
- 881
- Page End:
- 888
- Publication Date:
- 2018-04-06
- Subjects:
- atrial fibrillation -- catheter ablation -- far‐field -- mapping -- tissue proximity indicator -- voltage
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13472 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6990.xml