Refixation of osteochondral fractures by ultrasound-activated, resorbable pins: An ovine in vivo study. Issue 2 (February 2013)
- Record Type:
- Journal Article
- Title:
- Refixation of osteochondral fractures by ultrasound-activated, resorbable pins: An ovine in vivo study. Issue 2 (February 2013)
- Main Title:
- Refixation of osteochondral fractures by ultrasound-activated, resorbable pins
- Authors:
- Neumann, H.
Schulz, A. P.
Gille, J.
Klinger, M.
Jürgens, C.
Reimers, N.
Kienast, B. - Abstract:
- Abstract : Objectives: Osteochondral injuries, if not treated adequately, often lead to severe osteoarthritis. Possible treatment options include refixation of the fragment or replacement therapies such as Pridie drilling, microfracture or osteochondral grafts, all of which have certain disadvantages. Only refixation of the fragment can produce a smooth and resilient joint surface. The aim of this study was the evaluation of an ultrasound-activated bioresorbable pin for the refixation of osteochondral fragments under physiological conditions. Methods: In 16 Merino sheep, specific osteochondral fragments of the medial femoral condyle were produced and refixed with one of conventional bioresorbable pins, titanium screws or ultrasound-activated pins. Macro- and microscopic scoring was undertaken after three months. Results: The healing ratio with ultrasound-activated pins was higher than with conventional pins. No negative heat effect on cartilage has been shown. Conclusion: As the material is bioresorbable, no further surgery is required to remove the implant. MRI imaging is not compromised, as it is with implanted screws. The use of bioresorbable pins using ultrasound is a promising technology for the refixation of osteochondral fractures.
- Is Part Of:
- Bone & joint research. Volume 2:Issue 2(2013)
- Journal:
- Bone & joint research
- Issue:
- Volume 2:Issue 2(2013)
- Issue Display:
- Volume 2, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 2
- Issue:
- 2
- Issue Sort Value:
- 2013-0002-0002-0000
- Page Start:
- 26
- Page End:
- 32
- Publication Date:
- 2013-02
- Subjects:
- Osteochondral fracture -- Ultrasound-activated pin -- Bioresorbable implant -- Sheep study -- Cartilage -- Polylactide
Musculoskeletal system -- Periodicals
573.705 - Journal URLs:
- http://www.bjr.boneandjoint.org.uk/ ↗
- DOI:
- 10.1302/2046-3758.22.2000099 ↗
- Languages:
- English
- ISSNs:
- 2046-3758
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 7004.xml