Development and validation of a 3D-printed neuronavigation headset for therapeutic brain stimulation. (27th June 2018)
- Record Type:
- Journal Article
- Title:
- Development and validation of a 3D-printed neuronavigation headset for therapeutic brain stimulation. (27th June 2018)
- Main Title:
- Development and validation of a 3D-printed neuronavigation headset for therapeutic brain stimulation
- Authors:
- Mansouri, Farrokh
Mir-Moghtadaei, Arsalan
Niranjan, Vanathy
Wu, Jian Shu
Akhmedjanov, Daniyar
Nuh, Mishael
Cairo, Terri
Giacobbe, Peter
Zariffa, José
Downar, Jonathan - Abstract:
- Abstract: Background . Accurate neuronavigation is essential for optimal outcomes in therapeutic brain stimulation. MRI-guided neuronavigation, the current gold standard, requires access to MRI and frameless stereotaxic equipment, which is not available in all settings. Scalp-based heuristics depend on operator skill, with variable reproducibility across operators and sessions. An intermediate solution would offer superior reproducibility and ease-of-use to scalp measurements, without requiring MRI and frameless stereotaxy. Objective . We present and assess a novel neuronavigation method using commercially-available, inexpensive 3D head scanning, computer-aided design, and 3D-printing tools to fabricate form-fitted headsets for individuals that hold a stimulator, such as an rTMS coil, in the desired position over the scalp. Methods . 20 individuals underwent scanning for fabrication of individualized headsets designed for rTMS of the left dorsolateral prefrontal cortex (DLPFC). An experienced operator then performed three trials per participant of three neuronavigation methods: MRI-guided, scalp-measurement (BeamF3 method), and headset placement, and marked the sites obtained. Accuracy (versus MRI-guidance) and reproducibility were measured for each trial of each method. Results . Within-subject accuracy (against a gold-standard centroid of three MRI-guided localizations) for MRI-guided, scalp-measurement, and headset methods was 3.7 ± 1.6 mm, 14.8 ± 7.1 mm, andAbstract: Background . Accurate neuronavigation is essential for optimal outcomes in therapeutic brain stimulation. MRI-guided neuronavigation, the current gold standard, requires access to MRI and frameless stereotaxic equipment, which is not available in all settings. Scalp-based heuristics depend on operator skill, with variable reproducibility across operators and sessions. An intermediate solution would offer superior reproducibility and ease-of-use to scalp measurements, without requiring MRI and frameless stereotaxy. Objective . We present and assess a novel neuronavigation method using commercially-available, inexpensive 3D head scanning, computer-aided design, and 3D-printing tools to fabricate form-fitted headsets for individuals that hold a stimulator, such as an rTMS coil, in the desired position over the scalp. Methods . 20 individuals underwent scanning for fabrication of individualized headsets designed for rTMS of the left dorsolateral prefrontal cortex (DLPFC). An experienced operator then performed three trials per participant of three neuronavigation methods: MRI-guided, scalp-measurement (BeamF3 method), and headset placement, and marked the sites obtained. Accuracy (versus MRI-guidance) and reproducibility were measured for each trial of each method. Results . Within-subject accuracy (against a gold-standard centroid of three MRI-guided localizations) for MRI-guided, scalp-measurement, and headset methods was 3.7 ± 1.6 mm, 14.8 ± 7.1 mm, and 9.7 ± 5.2 mm respectively, with headsets significantly more accurate ( M = 5.1, p = 0.008) than scalp-measurement methods. Within-subject reproducibility (against the centroid of 3 localizations in the same modality) was 3.7 ± 1.6 mm (MRI), 4.2 ± 1.4 (scalp-measurement), and 1.4 ± 0.7 mm (headset), with headsets achieving significantly better reproducibility than either other method ( p < 0.0001). Conclusions . 3D-printed headsets may offer good accuracy, superior reproducibility and greater ease-of-use for stimulator placement over DLPFC, in settings where MRI-guidance is impractical. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 15:Number 4(2018:Aug.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 15:Number 4(2018:Aug.)
- Issue Display:
- Volume 15, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 15
- Issue:
- 4
- Issue Sort Value:
- 2018-0015-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-06-27
- Subjects:
- brain stimulation -- rTMS -- tDCS -- neuronavigation -- 3D printing -- 3D scanning
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2552/aacb96 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6993.xml