- Wang, Fengdan
Zhang, Yan
Xue, Huadan
Han, Wei
Yang, Xianda
Jin, Zhengyu
Zwar, Richard - Abstract:
- Background: Spinal fusion surgery is an important procedure for treating spinal diseases and computed tomography (CT) is a critical tool for postoperative evaluation. However, CT image quality is considerably impaired by metal artifacts and image noise. Purpose: To explore whether metal artifacts and image noise can be reduced by combining two technologies, adaptive statistical iterative reconstruction (ASIR) and monochromatic imaging generated by gemstone spectral imaging (GSI) dual-energy CT. Material and Methods: A total of 51 patients with 318 spinal pedicle screws were prospectively scanned by dual-energy CT using fast kV-switching GSI between 80 and 140 kVp. Monochromatic GSI images at 110 keV were reconstructed either without or with various levels of ASIR (30%, 50%, 70%, and 100%). The quality of five sets of images was objectively and subjectively assessed. Results: With objective image quality assessment, metal artifacts decreased when increasing levels of ASIR were applied ( P < 0.001). Moreover, adding ASIR to GSI also decreased image noise ( P < 0.001) and improved the signal-to-noise ratio ( P < 0.001). The subjective image quality analysis showed good inter-reader concordance, with intra-class correlation coefficients between 0.89 and 0.99. The visualization of peri-implant soft tissue was improved at higher ASIR levels ( P < 0.001). Conclusion: Combined use of ASIR and GSI decreased image noise and improved image quality in post-spinal fusion CT scans.Background: Spinal fusion surgery is an important procedure for treating spinal diseases and computed tomography (CT) is a critical tool for postoperative evaluation. However, CT image quality is considerably impaired by metal artifacts and image noise. Purpose: To explore whether metal artifacts and image noise can be reduced by combining two technologies, adaptive statistical iterative reconstruction (ASIR) and monochromatic imaging generated by gemstone spectral imaging (GSI) dual-energy CT. Material and Methods: A total of 51 patients with 318 spinal pedicle screws were prospectively scanned by dual-energy CT using fast kV-switching GSI between 80 and 140 kVp. Monochromatic GSI images at 110 keV were reconstructed either without or with various levels of ASIR (30%, 50%, 70%, and 100%). The quality of five sets of images was objectively and subjectively assessed. Results: With objective image quality assessment, metal artifacts decreased when increasing levels of ASIR were applied ( P < 0.001). Moreover, adding ASIR to GSI also decreased image noise ( P < 0.001) and improved the signal-to-noise ratio ( P < 0.001). The subjective image quality analysis showed good inter-reader concordance, with intra-class correlation coefficients between 0.89 and 0.99. The visualization of peri-implant soft tissue was improved at higher ASIR levels ( P < 0.001). Conclusion: Combined use of ASIR and GSI decreased image noise and improved image quality in post-spinal fusion CT scans. Optimal results were achieved with ASIR levels ≥70%. … (more)
- Is Part Of:
- Acta radiologica. Volume 58:Number 1(2017:Jan.)
- Journal:
- Acta radiologica
- Issue:
- Volume 58:Number 1(2017:Jan.)
- Issue Display:
- Volume 58, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 58
- Issue:
- 1
- Issue Sort Value:
- 2017-0058-0001-0000
- Page Start:
- 62
- Page End:
- 69
- Publication Date:
- 2017-01
- Subjects:
- Image noise -- metal artifacts -- dual-energy computed tomography -- iterative reconstruction
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185116631182 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6983.xml