The effect of multiple analysers on the biochemical diagnosis of myocardial infarction using a contemporary troponin–I assay. (November 2016)
- Record Type:
- Journal Article
- Title:
- The effect of multiple analysers on the biochemical diagnosis of myocardial infarction using a contemporary troponin–I assay. (November 2016)
- Main Title:
- The effect of multiple analysers on the biochemical diagnosis of myocardial infarction using a contemporary troponin–I assay
- Authors:
- Pethick, James
Patel, Prashanth
Davies, Timothy
Thompson, John
Nallagonda, Madhavi
Beech, Alison
Collinson, Paul
Lee, Virginia
Gupta, Pankaj - Abstract:
- Background: The measurement of cardiac troponin is central for the diagnosis of myocardial infarction (MI). It is recommended that a coefficient of variation of ≤10% is achieved at the diagnostic threshold and significant change between serial measurements reported. Many modern laboratories use multiple analysers linked by automation where samples are randomly assigned to an analyser. It is therefore important to consider the combined effect of all analysers on the analytical performance of troponin measurement. Method: The performance of a contemporary troponin-I (cTn-I) assay run on three analysers, linked by an automated track, was undertaken across a range of cTn-I concentrations. The data for the three analysers were aggregated to obtain the combined analytical coefficient of variation (CVA ) and reference change values (RCVs). Results: The CVA improved with increasing concentration and calculated RCVs ranged from 67.2% (±13 ng/L) to 32% (±160 ng/L) between cTn-I values 20 ng/L and 500 ng/L. Although there were significant differences in cTn-I measurement between analysers around the diagnostic threshold ( P < 0.05), the CVA was 13.6%. Conclusions: We demonstrate that there are significant differences between the performances of analysers which can impact the biochemical criteria for the diagnosis of MI. We also show that the RCV varies according to baseline cTn-I values and that reporting a single RCV across the analytical range of cTn-I may not be appropriate.
- Is Part Of:
- Annals of clinical biochemistry. Volume 53:Number 6(2016:Nov.)
- Journal:
- Annals of clinical biochemistry
- Issue:
- Volume 53:Number 6(2016:Nov.)
- Issue Display:
- Volume 53, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 53
- Issue:
- 6
- Issue Sort Value:
- 2016-0053-0006-0000
- Page Start:
- 702
- Page End:
- 705
- Publication Date:
- 2016-11
- Subjects:
- Troponin -- analytes -- statistics -- laboratory methods
Clinical chemistry -- Periodicals
Clinical biochemistry -- Periodicals
616.075 - Journal URLs:
- http://web.ebscohost.com/ehost/detail?sid=810a7788-77dd-439f-9630-ad7f5b199fd3%40sessionmgr4&vid=1&hid=14&bdata=JnNpdGU9ZWhvc3QtbGl2ZSZzY29wZT1zaXRl#db=mnh&jid=0324055 ↗
http://acb.rsmjournals.com ↗
http://www.usc.edu/hsc/nml/e-resources/info/annclib.html ↗
http://www.uk.sagepub.com/home.nav ↗
http://www.ingentaconnect.com/content/rsm/acb ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1177/0004563216637388 ↗
- Languages:
- English
- ISSNs:
- 0004-5632
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6965.xml