Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns. (October 2016)
- Record Type:
- Journal Article
- Title:
- Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns. (October 2016)
- Main Title:
- Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns
- Authors:
- Heitzmann, Daniel WW
Pieschel, Kai
Alimusaj, Merkur
Block, Julia
Putz, Cornelia
Wolf, Sebastian I - Abstract:
- Background: Shear stress at the stump in trans-tibial amputees induced by turning movements may be reduced with the use of torsion adapters in the prosthesis. Objective: Monitoring the motion and kinetic effects of a regular torsion adapter in comparison to a rigid placebo in unplanned spin and step turns. Study design: Single-blinded placebo-controlled cohort study. Methods: In total, 10 trans-tibial amputees underwent three-dimensional gait analysis in level walking and unplanned spin and step turns with a torsion adapter and with a rigid placebo. Results: Kinetic effects varied among participants. No statistically significant reduction of peak internal and peak external transverse plane moments was found for the torsion adapter in any walking condition. However, transverse plane rotation of the adapter was monitored in all participants. Conclusion: Motion between the socket and the residual limb may be reduced during turns due to transverse plane motion of the torsion adapter and shear stress on the residual limb may be reduced. However, there may be good and bad responders to torsion adapters due to differences in coupling between the residual limb and the socket. Clinical relevance: Strong coupling between stump and socket will help the user controlling his prosthesis. Shear stress at the stump may increase in stump–socket interface stiffness and may be the reason for residual limb problems. Torsion adapters therefore may be beneficial for comfort and stump condition inBackground: Shear stress at the stump in trans-tibial amputees induced by turning movements may be reduced with the use of torsion adapters in the prosthesis. Objective: Monitoring the motion and kinetic effects of a regular torsion adapter in comparison to a rigid placebo in unplanned spin and step turns. Study design: Single-blinded placebo-controlled cohort study. Methods: In total, 10 trans-tibial amputees underwent three-dimensional gait analysis in level walking and unplanned spin and step turns with a torsion adapter and with a rigid placebo. Results: Kinetic effects varied among participants. No statistically significant reduction of peak internal and peak external transverse plane moments was found for the torsion adapter in any walking condition. However, transverse plane rotation of the adapter was monitored in all participants. Conclusion: Motion between the socket and the residual limb may be reduced during turns due to transverse plane motion of the torsion adapter and shear stress on the residual limb may be reduced. However, there may be good and bad responders to torsion adapters due to differences in coupling between the residual limb and the socket. Clinical relevance: Strong coupling between stump and socket will help the user controlling his prosthesis. Shear stress at the stump may increase in stump–socket interface stiffness and may be the reason for residual limb problems. Torsion adapters therefore may be beneficial for comfort and stump condition in individual cases. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 40:Number 5(2016:Oct.)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 40:Number 5(2016:Oct.)
- Issue Display:
- Volume 40, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 5
- Issue Sort Value:
- 2016-0040-0005-0000
- Page Start:
- 558
- Page End:
- 565
- Publication Date:
- 2016-10
- Subjects:
- Lower limp amputee -- shear stress -- stump -- torsion adapter
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364615592698 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6946.xml