A biomimetic microfluidic model to study signalling between endothelial and vascular smooth muscle cells under hemodynamic conditions. Issue 11 (14th May 2018)
- Record Type:
- Journal Article
- Title:
- A biomimetic microfluidic model to study signalling between endothelial and vascular smooth muscle cells under hemodynamic conditions. Issue 11 (14th May 2018)
- Main Title:
- A biomimetic microfluidic model to study signalling between endothelial and vascular smooth muscle cells under hemodynamic conditions
- Authors:
- van Engeland, Nicole C. A.
Pollet, Andreas M. A. O.
den Toonder, Jaap M. J.
Bouten, Carlijn V. C.
Stassen, Oscar M. J. A.
Sahlgren, Cecilia M. - Abstract:
- Abstract : Cell signalling and mechanics influence vascular pathophysiology and there is an increasing demand for in vitro model systems that enable examination of signalling between vascular cells under hemodynamic conditions. Abstract : Cell signalling and mechanics influence vascular pathophysiology and there is an increasing demand for in vitro model systems that enable examination of signalling between vascular cells under hemodynamic conditions. Current 3D vessel wall constructs do not recapitulate the mechanical conditions of the native tissue nor do they allow examination of cell–cell interactions under relevant hemodynamic conditions. Here, we describe a 3D microfluidic chip model of arterial endothelial and smooth muscle cells where cellular organization, composition and interactions, as well as the mechanical environment of the arterial wall are mimicked. The hemodynamic EC–VSMC-signalling-on-a-chip consists of two parallel polydimethylsiloxane (PDMS) cell culture channels, separated by a flexible, porous PDMS membrane, mimicking the porosity of the internal elastic lamina. The hemodynamic EC–VSMC-signalling-on-a-chip allows co-culturing of human aortic endothelial cells (ECs) and human aortic vascular smooth muscle cells (VSMCs), separated by a porous membrane, which enables EC–VSMC interaction and signalling, crucial for the development and homeostasis of the vessel wall. The device allows real time cell imaging and control of hemodynamic conditions. The cultureAbstract : Cell signalling and mechanics influence vascular pathophysiology and there is an increasing demand for in vitro model systems that enable examination of signalling between vascular cells under hemodynamic conditions. Abstract : Cell signalling and mechanics influence vascular pathophysiology and there is an increasing demand for in vitro model systems that enable examination of signalling between vascular cells under hemodynamic conditions. Current 3D vessel wall constructs do not recapitulate the mechanical conditions of the native tissue nor do they allow examination of cell–cell interactions under relevant hemodynamic conditions. Here, we describe a 3D microfluidic chip model of arterial endothelial and smooth muscle cells where cellular organization, composition and interactions, as well as the mechanical environment of the arterial wall are mimicked. The hemodynamic EC–VSMC-signalling-on-a-chip consists of two parallel polydimethylsiloxane (PDMS) cell culture channels, separated by a flexible, porous PDMS membrane, mimicking the porosity of the internal elastic lamina. The hemodynamic EC–VSMC-signalling-on-a-chip allows co-culturing of human aortic endothelial cells (ECs) and human aortic vascular smooth muscle cells (VSMCs), separated by a porous membrane, which enables EC–VSMC interaction and signalling, crucial for the development and homeostasis of the vessel wall. The device allows real time cell imaging and control of hemodynamic conditions. The culture channels are surrounded on either side by vacuum channels to induce cyclic strain by applying cyclic suction, resulting in mechanical stretching and relaxation of the membrane in the cell culture channels. The blood flow is mimicked by creating a flow of medium at the EC side. Vascular cells remain viable during prolonged culturing, exhibit physiological morphology and organization and make cell–cell contact. During dynamic culturing of the device with a shear stress of 1–1.5 Pa and strain of 5–8%, VSMCs align perpendicular to the given strain in the direction of the flow and EC adopt a cobblestone morphology. To our knowledge, this is the first report on the development of a microfluidic device, which enables a co-culture of interacting ECs and VSMCs under hemodynamic conditions and presents a novel approach to systematically study the biological and mechanical components of the intimal-medial vascular unit. … (more)
- Is Part Of:
- Lab on a chip. Volume 18:Issue 11(2018)
- Journal:
- Lab on a chip
- Issue:
- Volume 18:Issue 11(2018)
- Issue Display:
- Volume 18, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 18
- Issue:
- 11
- Issue Sort Value:
- 2018-0018-0011-0000
- Page Start:
- 1607
- Page End:
- 1620
- Publication Date:
- 2018-05-14
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8lc00286j ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6948.xml