Morphometry and hemodynamics of posterior communicating artery aneurysms: Ruptured versus unruptured. (25th July 2018)
- Record Type:
- Journal Article
- Title:
- Morphometry and hemodynamics of posterior communicating artery aneurysms: Ruptured versus unruptured. (25th July 2018)
- Main Title:
- Morphometry and hemodynamics of posterior communicating artery aneurysms: Ruptured versus unruptured
- Authors:
- Huang, Xu
Liu, Donghui
Yin, Xiaoping
E, Yajun
Li, Zhiqiang
Tan, Wenchang
Huo, Yunlong - Abstract:
- Abstract: Posterior communicating artery (PCoA) aneurysms frequently rupture in small size (<7 mm). The aim of the study is to demonstrate morphometric and hemodynamic analyses in ruptured and unruptured PCoA aneurysms to improve predictive accuracy for rupture. Geometrical models were reconstructed from rotational DSA images of 57 ruptured and 22 unruptured side-wall PCoA aneurysms, which were classified into four two-dimensional (2D) groups by a combination of H/D and H/S ratios (H: dome height, D: dome diameter, and S: semi-axis height). Surface area ratio (SAR) of low time-averaged wall shear stress (TAWSS, ≤4 dynes cm −2 ) and high oscillatory shear index (OSI, ≥0.15) were computed in aneurysms. We hypothesized that a two-step analysis method, i.e., one-dimensionally morphometric and hemodynamic analyses in each 2D group, can enhance accuracy of PCoA aneurysm rupture evaluation. There was the highest incidence of H/D > 1 and H/S ≤ 2 with the largest surface area and SAR-TAWSS, but the lowest incidence of H/D ≤ 1 and H/S > 2 with the smallest surface area and SAR-TAWSS in ruptured PCoA aneurysms. PCoA aneurysms of H/D > 1 and H/S ≤ 2 with surface area > 70 mm 2, H/D ≤ 1 and H/S > 2 with neck diameter > 2.3 mm, H/D ≤ 1 and H/S ≤ 2 with aneurysmal height/parent diameter ratio > 1.0, and H/D > 1 and H/S > 2 with aneurysmal angle > 115° need special attention for clinical diagnosis and treatment. The study highlighted the importance of the two-step analysis method forAbstract: Posterior communicating artery (PCoA) aneurysms frequently rupture in small size (<7 mm). The aim of the study is to demonstrate morphometric and hemodynamic analyses in ruptured and unruptured PCoA aneurysms to improve predictive accuracy for rupture. Geometrical models were reconstructed from rotational DSA images of 57 ruptured and 22 unruptured side-wall PCoA aneurysms, which were classified into four two-dimensional (2D) groups by a combination of H/D and H/S ratios (H: dome height, D: dome diameter, and S: semi-axis height). Surface area ratio (SAR) of low time-averaged wall shear stress (TAWSS, ≤4 dynes cm −2 ) and high oscillatory shear index (OSI, ≥0.15) were computed in aneurysms. We hypothesized that a two-step analysis method, i.e., one-dimensionally morphometric and hemodynamic analyses in each 2D group, can enhance accuracy of PCoA aneurysm rupture evaluation. There was the highest incidence of H/D > 1 and H/S ≤ 2 with the largest surface area and SAR-TAWSS, but the lowest incidence of H/D ≤ 1 and H/S > 2 with the smallest surface area and SAR-TAWSS in ruptured PCoA aneurysms. PCoA aneurysms of H/D > 1 and H/S ≤ 2 with surface area > 70 mm 2, H/D ≤ 1 and H/S > 2 with neck diameter > 2.3 mm, H/D ≤ 1 and H/S ≤ 2 with aneurysmal height/parent diameter ratio > 1.0, and H/D > 1 and H/S > 2 with aneurysmal angle > 115° need special attention for clinical diagnosis and treatment. The study highlighted the importance of the two-step analysis method for clinical evaluation of PCoA aneurysm rupture. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 76(2018)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 76(2018)
- Issue Display:
- Volume 76, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 76
- Issue:
- 2018
- Issue Sort Value:
- 2018-0076-2018-0000
- Page Start:
- 35
- Page End:
- 44
- Publication Date:
- 2018-07-25
- Subjects:
- Intracranial aneurysm -- DSA -- Hemodynamics -- Morphology -- Risk factor of rupture
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2018.05.019 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6929.xml