A comparison of fine wire insertion techniques for deep finger flexor muscle electromyography. (August 2018)
- Record Type:
- Journal Article
- Title:
- A comparison of fine wire insertion techniques for deep finger flexor muscle electromyography. (August 2018)
- Main Title:
- A comparison of fine wire insertion techniques for deep finger flexor muscle electromyography
- Authors:
- Heales, Luke J.
Tucker, Kylie
Vicenzino, Bill
Hodges, Paul W.
MacDonald, David A. - Abstract:
- Abstract: Introduction: Intramuscular electromyography electrodes targeting flexor digitorum profundus (FDP) are inserted via the anterior or medial aspect of the forearm. These two methods pose different risks to neurovascular structures which overly FDP. This study aimed to compare the insertion depth and consider advantages and limitations of two different techniques to insert intramuscular electrodes into FDP. Methods: Using ultrasound imaging, neurovascular structures were identified along the path of FDP electrode insertion at the junction of the proximal and middle third of the ulna, bilaterally, in ten healthy individuals. Insertion depth was compared between the anterior and medial approaches for the mid muscle belly and targeted insertion to the index finger fascicle of FDP. Results: In our sample the ulnar artery was superficial to the FDP muscle when viewed anteriorly and was beyond the furthest border of FDP when viewed medially. Compared to the anterior approach, the medial insertion depth was 1.5 cm (95%CI 1.4–1.7, p < 0.001) less to the mid-belly of FDP and 0.6 cm (95%CI 0.4–0.7, p < 0.001) less to the index finger fascicle of FDP. Discussion: The medial approach involves less depth and lower risk for perforation of neurovascular structures when inserting intramuscular electrodes into the FDP muscle.
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 41(2018)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 41(2018)
- Issue Display:
- Volume 41, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 2018
- Issue Sort Value:
- 2018-0041-2018-0000
- Page Start:
- 77
- Page End:
- 81
- Publication Date:
- 2018-08
- Subjects:
- Electromyography -- Flexor digitorum profundus -- Intramuscular -- Fine wire -- EMG -- FDP
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2018.05.003 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6913.xml