Baseline adverse electrical remodeling and the risk for ventricular arrhythmia in Cardiac Resynchronization Therapy Recipients (MADIT CRT). (12th June 2018)
- Record Type:
- Journal Article
- Title:
- Baseline adverse electrical remodeling and the risk for ventricular arrhythmia in Cardiac Resynchronization Therapy Recipients (MADIT CRT). (12th June 2018)
- Main Title:
- Baseline adverse electrical remodeling and the risk for ventricular arrhythmia in Cardiac Resynchronization Therapy Recipients (MADIT CRT)
- Authors:
- Biton, Yitschak
Ng, Chee Yuan
Xia, Xiaojuan
Baman, Jayson R.
Couderc, Jean‐Philippe
Moss, Arthur J.
Kutyifa, Valentina
McNitt, Scott
Polonsky, Bronislava
Zareba, Wojciech - Abstract:
- Abstract: Introduction: Adverse electrical remodeling (AER), represented here as the sum absolute QRST integral (SAI QRST), has previously been shown to be directly associated with the risk for ventricular arrhythmia (VA). Cardiac resynchronization therapy (CRT) is known to reduce the risk for VA through various mechanisms, including reverse remodeling, and we aimed to evaluate the association between baseline AER and the risk for VA in CRT recipients. Methods and results: The study population comprised 961 CRT‐D implanted patients from the MADIT CRT study. The relationship between SAI QRST, VA risk, and VA risk/death was evaluated as a continuous and as a categorical variable–tertiles (T1 ≤ 0.527, T2 0.528–0.766, T3 > 0.766). In a multivariable model, AER was inversely associated with the risk of VA. Each unit increase in SAI QRST was associated with 64% (P = 0.007) and 54% (P = 0.003) decrease in the risk of VA and VA/death, respectively. Patients with high SAI QRST (T3) and medium SAI QRST (T2) had 52% (P < 0.001) and 32% (P = 0.027) reduced risk for VA and 44% (P = 0.002) and 26% (P = 0.055) reduced risk for VA/death as compared with patients with low SAI QRST (T1), respectively. Conclusion: In CRT implanted patients with mild heart failure, baseline AER was inversely associated with the risk for VA and VA/death; this is a finding that contradicts the relationship previously reported in non‐CRT implanted patients. We theorize that CRT may abate the process ofAbstract: Introduction: Adverse electrical remodeling (AER), represented here as the sum absolute QRST integral (SAI QRST), has previously been shown to be directly associated with the risk for ventricular arrhythmia (VA). Cardiac resynchronization therapy (CRT) is known to reduce the risk for VA through various mechanisms, including reverse remodeling, and we aimed to evaluate the association between baseline AER and the risk for VA in CRT recipients. Methods and results: The study population comprised 961 CRT‐D implanted patients from the MADIT CRT study. The relationship between SAI QRST, VA risk, and VA risk/death was evaluated as a continuous and as a categorical variable–tertiles (T1 ≤ 0.527, T2 0.528–0.766, T3 > 0.766). In a multivariable model, AER was inversely associated with the risk of VA. Each unit increase in SAI QRST was associated with 64% (P = 0.007) and 54% (P = 0.003) decrease in the risk of VA and VA/death, respectively. Patients with high SAI QRST (T3) and medium SAI QRST (T2) had 52% (P < 0.001) and 32% (P = 0.027) reduced risk for VA and 44% (P = 0.002) and 26% (P = 0.055) reduced risk for VA/death as compared with patients with low SAI QRST (T1), respectively. Conclusion: In CRT implanted patients with mild heart failure, baseline AER was inversely associated with the risk for VA and VA/death; this is a finding that contradicts the relationship previously reported in non‐CRT implanted patients. We theorize that CRT may abate the process of AER; however, characterization of this mechanism requires further study. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 29:Number 7(2018)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 29:Number 7(2018)
- Issue Display:
- Volume 29, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 7
- Issue Sort Value:
- 2018-0029-0007-0000
- Page Start:
- 1017
- Page End:
- 1023
- Publication Date:
- 2018-06-12
- Subjects:
- cardiac resynchronization therapy -- electrical remodeling -- heart failure -- MADIT CRT -- QRST -- ventricular arrhythmia
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13640 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6900.xml