Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration. (27th April 2015)
- Record Type:
- Journal Article
- Title:
- Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration. (27th April 2015)
- Main Title:
- Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration
- Authors:
- Sburlea, Andreea Ioana
Montesano, Luis
Minguez, Javier - Abstract:
- Abstract: Objective . Brain–computer interfaces (BCI) as a rehabilitation tool have been used to restore functions in patients with motor impairments by actively involving the central nervous system and triggering prosthetic devices according to the detected pre-movement state. However, since EEG signals are highly variable between subjects and recording sessions, typically a BCI is calibrated at the beginning of each session. This process is inconvenient especially for patients suffering locomotor disabilities in maintaining a bipedal position for a longer time. This paper presents a continuous EEG decoder of a pre-movement state in self-initiated walking and the usage of this decoder from session to session without recalibrating. Approach . Ten healthy subjects performed a self-initiated walking task during three sessions, with an intersession interval of one week. The implementation of our continuous decoder is based on the combination of movement-related cortical potential (MRCP) and event-related desynchronization (ERD) features with sparse classification models. Main results . During intrasession our technique detects the pre-movement state with 70% accuracy. Moreover this decoder can be applied from session to session without recalibration, with a decrease in performance of about 4% on a one- or two-week intersession interval. Significance . Our detection model operates in a continuous manner, which makes it a straightforward asset for rehabilitation scenarios. ByAbstract: Objective . Brain–computer interfaces (BCI) as a rehabilitation tool have been used to restore functions in patients with motor impairments by actively involving the central nervous system and triggering prosthetic devices according to the detected pre-movement state. However, since EEG signals are highly variable between subjects and recording sessions, typically a BCI is calibrated at the beginning of each session. This process is inconvenient especially for patients suffering locomotor disabilities in maintaining a bipedal position for a longer time. This paper presents a continuous EEG decoder of a pre-movement state in self-initiated walking and the usage of this decoder from session to session without recalibrating. Approach . Ten healthy subjects performed a self-initiated walking task during three sessions, with an intersession interval of one week. The implementation of our continuous decoder is based on the combination of movement-related cortical potential (MRCP) and event-related desynchronization (ERD) features with sparse classification models. Main results . During intrasession our technique detects the pre-movement state with 70% accuracy. Moreover this decoder can be applied from session to session without recalibration, with a decrease in performance of about 4% on a one- or two-week intersession interval. Significance . Our detection model operates in a continuous manner, which makes it a straightforward asset for rehabilitation scenarios. By using both temporal and spectral information we attained higher detection rates than the ones obtained with the MRCP and ERD detection models, both during the intrasession and intersession conditions. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 12:Number 3(2015:Jun.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 12:Number 3(2015:Jun.)
- Issue Display:
- Volume 12, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 12
- Issue:
- 3
- Issue Sort Value:
- 2015-0012-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-04-27
- Subjects:
- BCI -- motor intention -- rehabilitation -- session-to-session transfer -- MRCP -- ERD
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2560/12/3/036007 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6884.xml