Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease. (25th January 2018)
- Record Type:
- Journal Article
- Title:
- Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease. (25th January 2018)
- Main Title:
- Decreased inappropriate shocks with new generation ICDs in children and patients with congenital heart disease
- Authors:
- Goldstein, Stephanie A.
LaPage, Martin J.
Dechert, Brynn E.
Serwer, Gerald A.
Yu, Sunkyung
Lowery, Ray E.
Bradley, David J. - Abstract:
- Abstract: Objective: Inappropriate implantable cardioverter defibrillator (ICD) shocks in children and patients with congenital heart disease (CHD) remain a major complication of device therapy, occurring in as many as 50% of children with ICDs. New generation devices include algorithms designed to minimize inappropriate shocks. This study aimed to evaluate the effect of new generation ICDs on the incidence of inappropriate shocks in the pediatric and CHD population. Design: Retrospective study of patients with CHD or under age 25 receiving ICDs between 2000 and 2015. New generation ICDs were defined as those with Medtronic "SmartShock" algorithms. Results: Two hundred eight devices were implanted in 146 patients. Rates of inappropriate shocks were similar between diagnoses ( P = .71). The rate of inappropriate shock was 15% over median 5.8 years follow‐up. In the 36 patients (25%) with new generation ICDs, the rate of inappropriate shock was 6.3% over 4 years. Comparing old to new generation ICDs, freedom from first inappropriate shock was 90.6% versus 97.1% at 1 year and 80.4% versus 97.1% at 3 years ( P = .01). Lead fracture was associated with having inappropriate shock (hazard ratio 8.5, P < .0001), and there was no significant difference between the device groups when lead fractures were excluded. Clinical actions were taken in 69% of patients after initial inappropriate shock (such as medication or program change, system revision, or explant). When an action wasAbstract: Objective: Inappropriate implantable cardioverter defibrillator (ICD) shocks in children and patients with congenital heart disease (CHD) remain a major complication of device therapy, occurring in as many as 50% of children with ICDs. New generation devices include algorithms designed to minimize inappropriate shocks. This study aimed to evaluate the effect of new generation ICDs on the incidence of inappropriate shocks in the pediatric and CHD population. Design: Retrospective study of patients with CHD or under age 25 receiving ICDs between 2000 and 2015. New generation ICDs were defined as those with Medtronic "SmartShock" algorithms. Results: Two hundred eight devices were implanted in 146 patients. Rates of inappropriate shocks were similar between diagnoses ( P = .71). The rate of inappropriate shock was 15% over median 5.8 years follow‐up. In the 36 patients (25%) with new generation ICDs, the rate of inappropriate shock was 6.3% over 4 years. Comparing old to new generation ICDs, freedom from first inappropriate shock was 90.6% versus 97.1% at 1 year and 80.4% versus 97.1% at 3 years ( P = .01). Lead fracture was associated with having inappropriate shock (hazard ratio 8.5, P < .0001), and there was no significant difference between the device groups when lead fractures were excluded. Clinical actions were taken in 69% of patients after initial inappropriate shock (such as medication or program change, system revision, or explant). When an action was taken, subsequent inappropriate shock was reduced (5.3% vs 49.2% at 1 year; P = .002). Conclusions: Pediatric and CHD patients are experiencing reduced inappropriate shocks with new generation ICD systems, though reduced lead fracture may account for this improvement. Clinical interventions after inappropriate shock favorably impact the subsequent rate of shocks once an inappropriate shock occurs. … (more)
- Is Part Of:
- Congenital heart disease. Volume 13:Number 3(2018)
- Journal:
- Congenital heart disease
- Issue:
- Volume 13:Number 3(2018)
- Issue Display:
- Volume 13, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 13
- Issue:
- 3
- Issue Sort Value:
- 2018-0013-0003-0000
- Page Start:
- 413
- Page End:
- 418
- Publication Date:
- 2018-01-25
- Subjects:
- complication -- congenital heart disease -- ICD -- inappropriate shock -- lead fracture -- pediatric
Congenital heart disease -- Periodicals
616.1204305 - Journal URLs:
- https://www.techscience.com/journal/chd ↗
http://firstsearch.oclc.org ↗
http://proxy.library.carleton.ca/login?url=http://www3.interscience.wiley.com/cgi-bin/issn?DESCRIPTOR=PRINTISSN&VALUE=1747-079X ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/chd ↗
http://www.blackwell-synergy.com/toc/chd/1/3;jsessionid=bBP_cvinxU9dsOWrNX ↗ - DOI:
- 10.1111/chd.12585 ↗
- Languages:
- English
- ISSNs:
- 1747-079X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3410.683800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6900.xml