The acute effect of continuous positive airway pressure titration on blood pressure in awake overweight/obese patients with obstructive sleep apnoea. (4th July 2018)
- Record Type:
- Journal Article
- Title:
- The acute effect of continuous positive airway pressure titration on blood pressure in awake overweight/obese patients with obstructive sleep apnoea. (4th July 2018)
- Main Title:
- The acute effect of continuous positive airway pressure titration on blood pressure in awake overweight/obese patients with obstructive sleep apnoea
- Authors:
- Ratneswaran, Culadeeban
Pengo, Martino F.
Xiao, Sichang
Luo, Yuanming
Rossi, Gian Paolo
Polkey, Michael I.
Moxham, John
Steier, Joerg - Abstract:
- Abstract: Objectives: Continuous positive airway pressure (CPAP) improves upper airway obstruction in patients with obstructive sleep apnoea (OSA), who often are overweight-obese. Although it is thought that CPAP improves long-term blood pressure control (BP), the impact of acute and short-term CPAP use on the cardiovascular system in obese patients has not been described in detail. Methods: Obese patients (body mass index, BMI > 25 kg/m 2 ) with OSA were studied awake, supine during incremental CPAP titration (4–20 cmH2 O, +2 cmH2 O/3 mins). BP was measured continuously with a beat-to-beat BP monitor (Ohmeda 2300, Finapres Medical Systems, Amsterdam/NL), BP variability (BPV) was calculated as the standard deviation of BP at each CPAP level, the 95% confidence interval (95%CI) was calculated and changes in BP and BPV were reported. Results: 15 patients (12 male, 48 ± 10) years, BMI 38.9 ± 5.8 kg/m 2 ) were studied; the baseline BP was 131.0 ± 10.2/85.1 ± 9.1 mmHg. BP and BPV increased linearly with CPAP titration (systolic BP r = 0.960, p < .001; diastolic BP r = 0.961, p < .001; systolic BPV r = 0.662, p = .026; diastolic BPV r = 0.886, p < .001). The systolic BP increased by +17% (+23.15 (7.9, 38.4) mmHg; p = .011) and the diastolic BP by +23% (+18.27 (2.33, 34.21) mmHg; p = .009), when titrating CPAP to 20 cmH2 O. Systolic BPV increased by +96% (+5.10 (0.67, 9.53) mmHg; p < .001) and was maximal at 14 cmH2 O, and diastolic BPV by +97% (+3.02 (0.26, 5.78) mmHg;Abstract: Objectives: Continuous positive airway pressure (CPAP) improves upper airway obstruction in patients with obstructive sleep apnoea (OSA), who often are overweight-obese. Although it is thought that CPAP improves long-term blood pressure control (BP), the impact of acute and short-term CPAP use on the cardiovascular system in obese patients has not been described in detail. Methods: Obese patients (body mass index, BMI > 25 kg/m 2 ) with OSA were studied awake, supine during incremental CPAP titration (4–20 cmH2 O, +2 cmH2 O/3 mins). BP was measured continuously with a beat-to-beat BP monitor (Ohmeda 2300, Finapres Medical Systems, Amsterdam/NL), BP variability (BPV) was calculated as the standard deviation of BP at each CPAP level, the 95% confidence interval (95%CI) was calculated and changes in BP and BPV were reported. Results: 15 patients (12 male, 48 ± 10) years, BMI 38.9 ± 5.8 kg/m 2 ) were studied; the baseline BP was 131.0 ± 10.2/85.1 ± 9.1 mmHg. BP and BPV increased linearly with CPAP titration (systolic BP r = 0.960, p < .001; diastolic BP r = 0.961, p < .001; systolic BPV r = 0.662, p = .026; diastolic BPV r = 0.886, p < .001). The systolic BP increased by +17% (+23.15 (7.9, 38.4) mmHg; p = .011) and the diastolic BP by +23% (+18.27 (2.33, 34.21) mmHg; p = .009), when titrating CPAP to 20 cmH2 O. Systolic BPV increased by +96% (+5.10 (0.67, 9.53) mmHg; p < .001) and was maximal at 14 cmH2 O, and diastolic BPV by +97% (+3.02 (0.26, 5.78) mmHg; p < .001) at 16 cmH2 O. Conclusion: Short-term incremental CPAP leads to significant increases in BP and BPV in obese patients with OSA while awake. Careful titration of pressures is required to minimise the risk of nocturnal awakenings while improving BP control. … (more)
- Is Part Of:
- Blood pressure. Volume 27:Number 4(2018)
- Journal:
- Blood pressure
- Issue:
- Volume 27:Number 4(2018)
- Issue Display:
- Volume 27, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2018-0027-0004-0000
- Page Start:
- 206
- Page End:
- 214
- Publication Date:
- 2018-07-04
- Subjects:
- Hypertension -- variability -- sympathetic -- cardiovascular -- obesity
Blood pressure -- Periodicals
Hypertension -- Periodicals
Hypertension -- Periodicals
Blood Pressure -- Periodicals
612.14 - Journal URLs:
- http://informahealthcare.com/loi/blo ↗
http://www.tandf.co.uk/journals/titles/08037051.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/08037051.2018.1443391 ↗
- Languages:
- English
- ISSNs:
- 0803-7051
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.034000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6871.xml