Fracture strength testing of crowns made of CAD/CAM composite resins. Issue 3 (July 2018)
- Record Type:
- Journal Article
- Title:
- Fracture strength testing of crowns made of CAD/CAM composite resins. Issue 3 (July 2018)
- Main Title:
- Fracture strength testing of crowns made of CAD/CAM composite resins
- Authors:
- Okada, Ryota
Asakura, Masaki
Ando, Akihiro
Kumano, Hirokazu
Ban, Seiji
Kawai, Tatsushi
Takebe, Jun - Abstract:
- Abstract: Purpose: The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. Methods: The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. Results: The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3 kN to 3.9 kN, and was similar to that of IPS (3.3 kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175 MPa to 247 MPa, and was significantly lower than that of IPS (360 MPa). Conclusions: All CAD/CAM composite resin crowns studied presented about 3–4 times higher fracture strength than the average maximum bite force of the molar tooth (700–900 N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficientAbstract: Purpose: The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. Methods: The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. Results: The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3 kN to 3.9 kN, and was similar to that of IPS (3.3 kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175 MPa to 247 MPa, and was significantly lower than that of IPS (360 MPa). Conclusions: All CAD/CAM composite resin crowns studied presented about 3–4 times higher fracture strength than the average maximum bite force of the molar tooth (700–900 N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 62:Issue 3(2018)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 62:Issue 3(2018)
- Issue Display:
- Volume 62, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 62
- Issue:
- 3
- Issue Sort Value:
- 2018-0062-0003-0000
- Page Start:
- 287
- Page End:
- 292
- Publication Date:
- 2018-07
- Subjects:
- CAD/CAM -- Fracture strength -- Composite resin -- Biaxial flexural strength
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2017.10.003 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6862.xml