Homogeneous vs. patient specific breast models for Monte Carlo evaluation of mean glandular dose in mammography. (July 2018)
- Record Type:
- Journal Article
- Title:
- Homogeneous vs. patient specific breast models for Monte Carlo evaluation of mean glandular dose in mammography. (July 2018)
- Main Title:
- Homogeneous vs. patient specific breast models for Monte Carlo evaluation of mean glandular dose in mammography
- Authors:
- Sarno, A.
Mettivier, G.
Di Lillo, F.
Bliznakova, K.
Sechopoulos, I.
Russo, P. - Abstract:
- Highlights: Homogeneous breast models for MGD were compared with patient specific breast phantoms. The difference between the MGD for homogeneous and patient specific breast model was between −43% and +28%. The employed spectra present a slight influence on the MGD estimates differences. Abstract: Purpose: To compare, via Monte Carlo simulations, homogeneous and non-homogenous breast models adopted for mean glandular dose (MGD) estimates in mammography vs. patient specific digital breast phantoms. Methods: We developed a GEANT4 Monte Carlo code simulating four homogenous cylindrical breast models featured as follows: (1) semi-cylindrical section enveloped in a 5-mm adipose layer; (2) semi-elliptical section with a 4-mm thick skin; (3) semi-cylindrical section with a 1.45-mm skin layer; (4) semi-cylindrical section in a 1.45-mm skin layer and 2-mm subcutaneous adipose layer. Twenty patient specific digital breast phantoms produced from a dedicated CT scanner were assumed as reference in the comparison. We simulated two spectra produced from two anode/filter combinations. An additional digital breast phantom was produced via BreastSimulator software. Results: With reference to the results for patient-specific breast phantoms and for W/Al spectra, models #1 and #3 showed higher MGD values by about 1% (ranges [–33%; +28%] and [−31%; +30%], respectively), while for model #4 it was 2% lower (range [−34%; +26%]) and for model #2 –11% (range [−39%; +14%]), on average. On the otherHighlights: Homogeneous breast models for MGD were compared with patient specific breast phantoms. The difference between the MGD for homogeneous and patient specific breast model was between −43% and +28%. The employed spectra present a slight influence on the MGD estimates differences. Abstract: Purpose: To compare, via Monte Carlo simulations, homogeneous and non-homogenous breast models adopted for mean glandular dose (MGD) estimates in mammography vs. patient specific digital breast phantoms. Methods: We developed a GEANT4 Monte Carlo code simulating four homogenous cylindrical breast models featured as follows: (1) semi-cylindrical section enveloped in a 5-mm adipose layer; (2) semi-elliptical section with a 4-mm thick skin; (3) semi-cylindrical section with a 1.45-mm skin layer; (4) semi-cylindrical section in a 1.45-mm skin layer and 2-mm subcutaneous adipose layer. Twenty patient specific digital breast phantoms produced from a dedicated CT scanner were assumed as reference in the comparison. We simulated two spectra produced from two anode/filter combinations. An additional digital breast phantom was produced via BreastSimulator software. Results: With reference to the results for patient-specific breast phantoms and for W/Al spectra, models #1 and #3 showed higher MGD values by about 1% (ranges [–33%; +28%] and [−31%; +30%], respectively), while for model #4 it was 2% lower (range [−34%; +26%]) and for model #2 –11% (range [−39%; +14%]), on average. On the other hand, for W/Rh spectra, models #1 and #4 showed lower MGD values by 2% and 1%, while for model #2 and #3 it was 14% and 8% lower, respectively (ranges [−43%; +13%] and [−41%; +21%]). The simulation with the digital breast phantom produced with BreastSimulator showed a MGD overestimation of +33%. Conclusions: The homogeneous breast models led to maximum MGD underestimation and overestimation of 43% and 28%, respectively, when compared to patient specific breast phantoms derived from clinical CT scans. … (more)
- Is Part Of:
- Physica medica. Volume 51(2018)
- Journal:
- Physica medica
- Issue:
- Volume 51(2018)
- Issue Display:
- Volume 51, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 51
- Issue:
- 2018
- Issue Sort Value:
- 2018-0051-2018-0000
- Page Start:
- 56
- Page End:
- 63
- Publication Date:
- 2018-07
- Subjects:
- Breast models -- Mean glandular dose -- Mammography -- Monte Carlo simulations
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.392 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6858.xml