Multivariate approach for estimating the local spectral F-test and its application to the EEG during photic stimulation. (August 2018)
- Record Type:
- Journal Article
- Title:
- Multivariate approach for estimating the local spectral F-test and its application to the EEG during photic stimulation. (August 2018)
- Main Title:
- Multivariate approach for estimating the local spectral F-test and its application to the EEG during photic stimulation
- Authors:
- Felix, Leonardo Bonato
Rocha, Paulo Fábio Figueiredo
Mendes, Eduardo Mazoni Andrade Marçal
Miranda de Sá, Antonio Mauricio Ferreira Leite - Abstract:
- Highlights: The sum of N local spectral F -tests is proposed as new evoked response detector. The detector performance always improves using simulated signals. Results with EEG data also indicate better performance in detection for N > 2. Abstract: Background and objective: The local spectral F-test (SFT) corresponds to a statistical way of assessing whether the spectrum of a signal is flat in the vicinity of a specific frequency. The power of this univariate test (comparing one frequency component against its neighbours using only one signal) depends on the signal-to-noise ratio, which is fixed in the case of electroencephalogram (EEG) analysis. However, this limitation could be overcome by considering more signals in the analysis. Thus, this work presents an alternative multivariate approach for estimating the local SFT. Methods: Probabilities of detection and false alarm studies were performed for this new detector using Monte Carlo simulations and theoretically whenever possible. The application was illustrated in recorded EEG data collected during photic stimulation. Results: The results showed that it is worth using more channels if available, since the probability of detecting a response tends to increase with increasing number of signals. In the application to the EEG during photic stimulation, the best results were obtained by using N > 2 signals (around 30% more accurate when compared with the univariate case. The false positive levels were maintained below 5%).Highlights: The sum of N local spectral F -tests is proposed as new evoked response detector. The detector performance always improves using simulated signals. Results with EEG data also indicate better performance in detection for N > 2. Abstract: Background and objective: The local spectral F-test (SFT) corresponds to a statistical way of assessing whether the spectrum of a signal is flat in the vicinity of a specific frequency. The power of this univariate test (comparing one frequency component against its neighbours using only one signal) depends on the signal-to-noise ratio, which is fixed in the case of electroencephalogram (EEG) analysis. However, this limitation could be overcome by considering more signals in the analysis. Thus, this work presents an alternative multivariate approach for estimating the local SFT. Methods: Probabilities of detection and false alarm studies were performed for this new detector using Monte Carlo simulations and theoretically whenever possible. The application was illustrated in recorded EEG data collected during photic stimulation. Results: The results showed that it is worth using more channels if available, since the probability of detecting a response tends to increase with increasing number of signals. In the application to the EEG during photic stimulation, the best results were obtained by using N > 2 signals (around 30% more accurate when compared with the univariate case. The false positive levels were maintained below 5%). Conclusion: Consequently, it is conjectured that it is always better to apply the proposed method if more than one EEG signal with the same signal-to-noise ratio (SNR) is available. For the case where the SNRs are different, a guideline has been given to improve the detection. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 162(2018)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 162(2018)
- Issue Display:
- Volume 162, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 162
- Issue:
- 2018
- Issue Sort Value:
- 2018-0162-2018-0000
- Page Start:
- 87
- Page End:
- 91
- Publication Date:
- 2018-08
- Subjects:
- Local spectral F-test -- Objective response detection -- Electroencephalogram
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2018.05.010 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6854.xml