Pilot Study of the Effects of Ambient Light Level Variation on Spectral Domain Anterior Segment OCT-Derived Angle Metrics in Caucasians versus Asians. (3rd July 2018)
- Record Type:
- Journal Article
- Title:
- Pilot Study of the Effects of Ambient Light Level Variation on Spectral Domain Anterior Segment OCT-Derived Angle Metrics in Caucasians versus Asians. (3rd July 2018)
- Main Title:
- Pilot Study of the Effects of Ambient Light Level Variation on Spectral Domain Anterior Segment OCT-Derived Angle Metrics in Caucasians versus Asians
- Authors:
- Dastiridou, Anna
Marion, Kenneth
Niemeyer, Moritz
Francis, Brian
Sadda, Srinivas
Chopra, Vikas - Abstract:
- ABSTRACT: Purpose: To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Materials and Methods: Caucasian ( n = 24) and Asian participants of Chinese ancestry ( n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Results: Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2, respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group ( p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all pABSTRACT: Purpose: To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Materials and Methods: Caucasian ( n = 24) and Asian participants of Chinese ancestry ( n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Results: Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2, respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group ( p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all p -values >0.3). Conclusion: SL-based angle dimensions using SD-OCT are sensitive to changes in ambient illumination in participants with Caucasian and Asian ancestry. Although Caucasian eyes had larger baseline angle opening under bright light conditions, the light-to-dark change in angle dimensions was similar in the two groups. … (more)
- Is Part Of:
- Current eye research. Volume 43:Number 7(2018)
- Journal:
- Current eye research
- Issue:
- Volume 43:Number 7(2018)
- Issue Display:
- Volume 43, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 43
- Issue:
- 7
- Issue Sort Value:
- 2018-0043-0007-0000
- Page Start:
- 955
- Page End:
- 959
- Publication Date:
- 2018-07-03
- Subjects:
- Anterior chamber angle -- anterior-segment OCT -- optical coherence tomography -- glaucoma -- imaging
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02713683.2018.1464192 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6762.xml