Evaluation of a magnetic resonance guided linear accelerator for stereotactic radiosurgery treatment. Issue 3 (June 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of a magnetic resonance guided linear accelerator for stereotactic radiosurgery treatment. Issue 3 (June 2018)
- Main Title:
- Evaluation of a magnetic resonance guided linear accelerator for stereotactic radiosurgery treatment
- Authors:
- Wen, Ning
Kim, Joshua
Doemer, Anthony
Glide-Hurst, Carri
Chetty, Indrin J.
Liu, Chang
Laugeman, Eric
Xhaferllari, Ilma
Kumarasiri, Akila
Victoria, James
Bellon, Maria
Kalkanis, Steve
Siddiqui, M. Salim
Movsas, Benjamin - Abstract:
- Abstract: Introduction: The purpose of this study was to investigate the systematic localization accuracy, treatment planning capability, and delivery accuracy of an integrated magnetic resonance imaging guided Linear Accelerator (MR-Linac) platform for stereotactic radiosurgery. Materials and methods: The phantom for the end-to-end test comprises three different compartments: a rectangular MR/CT target phantom, a Winston–Lutz cube, and a rectangular MR/CT isocenter phantom. Hidden target tests were performed at gantry angles of 0, 90, 180, and 270 degrees to quantify the systematic accuracy. Five patient plans with a total of eleven lesions were used to evaluate the dosimetric accuracy. Single-isocenter IMRT treatment plans using 10–15 coplanar beams were generated to treat the multiple metastases. Results: The end-to-end localization accuracy of the system was 1.0 ± 0.1 mm. The conformity index, homogeneity index and gradient index of the plans were 1.26 ± 0.22, 1.22 ± 0.10, and 5.38 ± 1.44, respectively. The average absolute point dose difference between measured and calculated dose was 1.64 ± 1.90%, and the mean percentage of points passing the 3%/1 mm gamma criteria was 96.87%. Conclusions: Our experience demonstrates that excellent plan quality and delivery accuracy was achievable on the MR-Linac for treating multiple brain metastases with a single isocenter.
- Is Part Of:
- Radiotherapy and oncology. Volume 127:Issue 3(2018)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 127:Issue 3(2018)
- Issue Display:
- Volume 127, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 127
- Issue:
- 3
- Issue Sort Value:
- 2018-0127-0003-0000
- Page Start:
- 460
- Page End:
- 466
- Publication Date:
- 2018-06
- Subjects:
- MR-Linac -- Stereotactic radiosurgery -- Accuracy -- Single isocenter multiple targets
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2018.04.034 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6775.xml