Robust optimization in lung treatment plans accounting for geometric uncertainty. (10th March 2018)
- Record Type:
- Journal Article
- Title:
- Robust optimization in lung treatment plans accounting for geometric uncertainty. (10th March 2018)
- Main Title:
- Robust optimization in lung treatment plans accounting for geometric uncertainty
- Authors:
- Zhang, Xin
Rong, Yi
Morrill, Steven
Fang, Jian
Narayanasamy, Ganesh
Galhardo, Edvaldo
Maraboyina, Sanjay
Croft, Christopher
xia, Fen
Penagaricano, Jose - Abstract:
- Abstract: Robust optimization generates scenario‐based plans by a minimax optimization method to find optimal scenario for the trade‐off between target coverage robustness and organ‐at‐risk (OAR) sparing. In this study, 20 lung cancer patients with tumors located at various anatomical regions within the lungs were selected and robust optimization photon treatment plans including intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. The plan robustness was analyzed using perturbed doses with setup error boundary of ±3 mm in anterior/posterior (AP), ±3 mm in left/right (LR), and ±5 mm in inferior/superior (IS) directions from isocenter. Perturbed doses for D99, D98, and D95 were computed from six shifted isocenter plans to evaluate plan robustness. Dosimetric study was performed to compare the internal target volume‐based robust optimization plans (ITV‐IMRT and ITV‐VMAT) and conventional PTV margin‐based plans (PTV‐IMRT and PTV‐VMAT). The dosimetric comparison parameters were: ITV target mean dose (Dmean ), R95 (D95 /Dprescription ), Paddick's conformity index (CI), homogeneity index (HI), monitor unit (MU), and OAR doses including lung (Dmean, V20 Gy and V15 Gy ), chest wall, heart, esophagus, and maximum cord doses. A comparison of optimization results showed the robust optimization plan had better ITV dose coverage, better CI, worse HI, and lower OAR doses than conventional PTV margin‐based plans. Plan robustnessAbstract: Robust optimization generates scenario‐based plans by a minimax optimization method to find optimal scenario for the trade‐off between target coverage robustness and organ‐at‐risk (OAR) sparing. In this study, 20 lung cancer patients with tumors located at various anatomical regions within the lungs were selected and robust optimization photon treatment plans including intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. The plan robustness was analyzed using perturbed doses with setup error boundary of ±3 mm in anterior/posterior (AP), ±3 mm in left/right (LR), and ±5 mm in inferior/superior (IS) directions from isocenter. Perturbed doses for D99, D98, and D95 were computed from six shifted isocenter plans to evaluate plan robustness. Dosimetric study was performed to compare the internal target volume‐based robust optimization plans (ITV‐IMRT and ITV‐VMAT) and conventional PTV margin‐based plans (PTV‐IMRT and PTV‐VMAT). The dosimetric comparison parameters were: ITV target mean dose (Dmean ), R95 (D95 /Dprescription ), Paddick's conformity index (CI), homogeneity index (HI), monitor unit (MU), and OAR doses including lung (Dmean, V20 Gy and V15 Gy ), chest wall, heart, esophagus, and maximum cord doses. A comparison of optimization results showed the robust optimization plan had better ITV dose coverage, better CI, worse HI, and lower OAR doses than conventional PTV margin‐based plans. Plan robustness evaluation showed that the perturbed doses of D99, D98, and D95 were all satisfied at least 99% of the ITV to received 95% of prescription doses. It was also observed that PTV margin‐based plans had higher MU than robust optimization plans. The results also showed robust optimization can generate plans that offer increased OAR sparing, especially for normal lungs and OARs near or abutting the target. Weak correlation was found between normal lung dose and target size, and no other correlation was observed in this study. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 3(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 3(2018)
- Issue Display:
- Volume 19, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 3
- Issue Sort Value:
- 2018-0019-0003-0000
- Page Start:
- 19
- Page End:
- 26
- Publication Date:
- 2018-03-10
- Subjects:
- dosimetric comparison -- RayStation -- robust optimization -- treatment planning system
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12291 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6800.xml