Film‐based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom. (30th March 2018)
- Record Type:
- Journal Article
- Title:
- Film‐based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom. (30th March 2018)
- Main Title:
- Film‐based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom
- Authors:
- Pan, Yuxi
Yang, Ruijie
Li, Jun
Zhang, Xile
Liu, Lu
Wang, Junjie - Abstract:
- Abstract: Monte Carlo (MC) simulation, as the most accurate dose calculation algorithm, is available in the MultiPlan treatment planning system for Cyberknife. The main purpose of this work was to perform experiments to thoroughly investigate the accuracy of the MC dose calculation algorithm. Besides the basic MC beam commissioning, two test scenarios were designed. First, single beam tests were performed with a solid water phantom to verify the MC source model in simple geometry. Then, a lung treatment plan on a CIRS thorax phantom was created to mimic the clinical patient treatment. The plan was optimized and calculated using ray tracing (RT) algorithm and then recalculated using MC algorithm. Measurements were performed in both a homogeneous phantom and a heterogeneous phantom (CIRS). Ion‐chamber and radiochromic film were used to obtain absolute point dose and dose distributions. Ion‐chamber results showed that the differences between measured and MC calculated dose were within 3% for all tests. On the film measurements, MC calculation results showed good agreements with the measured dose for all single beam tests. As for the lung case, the gamma passing rate between measured and MC calculated dose was 98.31% and 97.28% for homogeneous and heterogeneous situation, respectively, using 3%/2 mm criteria. However, RT algorithm failed with the passing rate of 79.25% (3%/2 mm) for heterogeneous situation. These results demonstrated that MC dose calculation algorithm in theAbstract: Monte Carlo (MC) simulation, as the most accurate dose calculation algorithm, is available in the MultiPlan treatment planning system for Cyberknife. The main purpose of this work was to perform experiments to thoroughly investigate the accuracy of the MC dose calculation algorithm. Besides the basic MC beam commissioning, two test scenarios were designed. First, single beam tests were performed with a solid water phantom to verify the MC source model in simple geometry. Then, a lung treatment plan on a CIRS thorax phantom was created to mimic the clinical patient treatment. The plan was optimized and calculated using ray tracing (RT) algorithm and then recalculated using MC algorithm. Measurements were performed in both a homogeneous phantom and a heterogeneous phantom (CIRS). Ion‐chamber and radiochromic film were used to obtain absolute point dose and dose distributions. Ion‐chamber results showed that the differences between measured and MC calculated dose were within 3% for all tests. On the film measurements, MC calculation results showed good agreements with the measured dose for all single beam tests. As for the lung case, the gamma passing rate between measured and MC calculated dose was 98.31% and 97.28% for homogeneous and heterogeneous situation, respectively, using 3%/2 mm criteria. However, RT algorithm failed with the passing rate of 79.25% (3%/2 mm) for heterogeneous situation. These results demonstrated that MC dose calculation algorithm in the Multiplan system is accurate enough for patient dose calculation. It is strongly recommended to use MC algorithm in heterogeneous media. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 3(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 3(2018)
- Issue Display:
- Volume 19, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 3
- Issue Sort Value:
- 2018-0019-0003-0000
- Page Start:
- 142
- Page End:
- 148
- Publication Date:
- 2018-03-30
- Subjects:
- Cyberknife -- film measurement -- heterogeneous phantom -- Monte Carlo
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12314 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6799.xml