Setup errors in radiation therapy for thoracic tumor patients of different body mass index. (1st March 2018)
- Record Type:
- Journal Article
- Title:
- Setup errors in radiation therapy for thoracic tumor patients of different body mass index. (1st March 2018)
- Main Title:
- Setup errors in radiation therapy for thoracic tumor patients of different body mass index
- Authors:
- Zhao, Jin
Zhang, Mingyun
Zhai, Fushan
Wang, Haiyan
Li, Xingde - Abstract:
- Abstract: Purpose: To assess the setup errors in radiation therapy for thoracic tumors patients of different somatotypes, and to seek an individualized mathematical basis for defining the planning target volume (PTV). Methods: Sixty patients with thoracic tumors were divided into four somatotypes according to their body mass index (BMI), and their body positions were setup by two groups of technicians independently. CT simulations were performed and the reconstructed radiography was digitally generated as reference images for location verification and error measurement. By setting positioning error ranges, the within‐range positioning correction rate was compared among groups. Results: Position setups for patients in the emaciated group, moderate group, and overweight group were relatively stable (with minor setup error differences between the two groups of technicians). In emaciated group, moderate group, overweight group, and obese group, setup errors in the right–left direction (R‐L) were 2.2 ± 1.3 mm, 2.2 ± 1.6 mm, 3.9 ± 3.1 mm, and 8.8 ± 3.5 mm, respectively; whereas the setup errors in the four groups in the superior–inferior(S‐I) direction were 2.4 ± 1.8 mm, 2.1 ± 1.9 mm, 3.2 ± 2.6 mm, and 5.4 ± 3.5 mm, and in the anterior–posterior (A‐P) direction were 2.2 ± 1.7 mm, 1.9 ± 1.9 mm, 3.2 ± 2.9 mm, and 6.2 ± 4.2 mm, respectively. Moreover, in the moderate group, the positioning correction rate in the three directions (R‐L, S‐I, and A‐P) was 20%, 9%, 8% within the errorAbstract: Purpose: To assess the setup errors in radiation therapy for thoracic tumors patients of different somatotypes, and to seek an individualized mathematical basis for defining the planning target volume (PTV). Methods: Sixty patients with thoracic tumors were divided into four somatotypes according to their body mass index (BMI), and their body positions were setup by two groups of technicians independently. CT simulations were performed and the reconstructed radiography was digitally generated as reference images for location verification and error measurement. By setting positioning error ranges, the within‐range positioning correction rate was compared among groups. Results: Position setups for patients in the emaciated group, moderate group, and overweight group were relatively stable (with minor setup error differences between the two groups of technicians). In emaciated group, moderate group, overweight group, and obese group, setup errors in the right–left direction (R‐L) were 2.2 ± 1.3 mm, 2.2 ± 1.6 mm, 3.9 ± 3.1 mm, and 8.8 ± 3.5 mm, respectively; whereas the setup errors in the four groups in the superior–inferior(S‐I) direction were 2.4 ± 1.8 mm, 2.1 ± 1.9 mm, 3.2 ± 2.6 mm, and 5.4 ± 3.5 mm, and in the anterior–posterior (A‐P) direction were 2.2 ± 1.7 mm, 1.9 ± 1.9 mm, 3.2 ± 2.9 mm, and 6.2 ± 4.2 mm, respectively. Moreover, in the moderate group, the positioning correction rate in the three directions (R‐L, S‐I, and A‐P) was 20%, 9%, 8% within the error range of 5–10 mm, and 3%, 0%, 1% with a more than 10 mm error range. However, in overweight group and obese group, the positioning correction rate in these three directions (also with a more than 10 mm error range) was 23%, 27%, 19% and 21%, 16%, 23%, respectively. Conclusions: In radiation therapy for patients with thoracic tumors, the definition of PTV should be individualized. Meanwhile, with the increase in BMI, positioning correction rate has a tendency to rise too. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 3(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 3(2018)
- Issue Display:
- Volume 19, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 3
- Issue Sort Value:
- 2018-0019-0003-0000
- Page Start:
- 27
- Page End:
- 31
- Publication Date:
- 2018-03-01
- Subjects:
- body mass index (BMI) -- radiation therapy -- setup errors -- thoracic tumor
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12270 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6799.xml