Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea. (9th November 2017)
- Record Type:
- Journal Article
- Title:
- Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea. (9th November 2017)
- Main Title:
- Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea
- Authors:
- Mackenzie, David C.
Nasrin, Sabiha
Atika, Bita
Modi, Payal
Alam, Nur H.
Levine, Adam C. - Abstract:
- Abstract : Objectives: Unstructured clinical assessments of dehydration in children are inaccurate. Point‐of‐care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh. Methods: Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%–9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration. Results: A total of 350 children (0–60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295–351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time andAbstract : Objectives: Unstructured clinical assessments of dehydration in children are inaccurate. Point‐of‐care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh. Methods: Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%–9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration. Results: A total of 350 children (0–60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295–351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration. Conclusions: The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 37:Number 6(2018)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 37:Number 6(2018)
- Issue Display:
- Volume 37, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2018-0037-0006-0000
- Page Start:
- 1397
- Page End:
- 1402
- Publication Date:
- 2017-11-09
- Subjects:
- diarrhea -- emergency medicine -- global health -- hemodynamics -- pediatrics -- point of care -- ultrasound -- volume status
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.14478 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6806.xml