Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement. (October 2016)
- Record Type:
- Journal Article
- Title:
- Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement. (October 2016)
- Main Title:
- Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement
- Authors:
- Rieß, Henrik Christian
Kölbel, Tilo
Diener, Holger
Heidemann, Franziska
Debus, E. Sebastian
Rohlffs, Fiona
Tsilimparis, Nikolaos - Abstract:
- Purpose: To report implantation of an iliac branch device (IBD) for preserving antegrade blood flow to a sole internal iliac artery (IIA) via an ipsilateral approach during endovascular repair to reline an aortobi-iliac allograft.Technique: The technique is described in a 55-year-old man with an enteric fistula involving an aortobi-iliac Y-prosthesis. After complete excision, the prosthesis was replaced by an allograft. Due to rebleeding and resuturing of the graft, total stent-graft relining of the allograft was planned with preservation of the sole left IIA using an iliac side branch (ZBIS). During introduction of a 12-F sheath over the allograft's neobifurcation to establish a femorofemoral through-and-through approach, the allograft ruptured. A compliant balloon was inflated to control the hemorrhage. The IBD was first fully deployed, followed by stent-graft relining. Consequently, stent-graft implantation in the left IIA using a crossover maneuver was no longer feasible, so a 0.035-inch super stiff wire was introduced through the IBD's 20-F sheath. A 12-mm semi-compliant balloon was inflated in the common iliac artery above the iliac branch to act as an abutment for a 7-F sheath to run over the stiff wire into the IIA for delivery/deployment of a stent-graft.Conclusion: It is feasible to use a complete ipsilateral femoral approach for IBD implantation after aortic stent-graft placement.
- Is Part Of:
- Journal of endovascular therapy. Volume 23:Number 5(2016:Oct.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 23:Number 5(2016:Oct.)
- Issue Display:
- Volume 23, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2016-0023-0005-0000
- Page Start:
- 800
- Page End:
- 802
- Publication Date:
- 2016-10
- Subjects:
- allograft -- aortic rupture -- buddy wire -- iliac branch device -- internal iliac artery -- ipsilateral approach -- relining -- prosthetic graft -- stent-graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816656449 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6769.xml