Tissue shrinkage in microwave thermal ablation: comparison of three commercial devices. (19th May 2018)
- Record Type:
- Journal Article
- Title:
- Tissue shrinkage in microwave thermal ablation: comparison of three commercial devices. (19th May 2018)
- Main Title:
- Tissue shrinkage in microwave thermal ablation: comparison of three commercial devices
- Authors:
- Farina, Laura
Nissenbaum, Yitzhak
Cavagnaro, Marta
Goldberg, S. Nahum - Abstract:
- Abstract: Purpose : To evaluate, characterise and compare the extent of tissue shrinkage induced from three different commercial microwave ablation devices, and to elucidate the mechanism behind the distinctive performances obtained. Materials and methods: Microwave ablation ( N = 152) was conducted with three different commercial devices on cubes of ex vivo liver (10–40 ± 2 mm/side) embedded in agar phantoms. 50–60 W was applied for 1–10 min duration. Pre- and post-ablation dimensions of the samples, as well as the extent of carbonisation and coagulation were measured and correlated. ANOVA was performed to evaluate statistical significance. Results: For all devices, logarithmic correlations with time were observed for both tissue shrinkage ( R 2 = 0.84–1.00) and induced carbonisation ( R 2 = 0.73–0.99) radially to the antenna axis. Along the longitudinal axis of the antenna, for two of the devices shrinkage did not appreciably change with time ( p > 0.05), yet carbonisation increased linearly ( R 2 = 0.57–0.94). For the third fully internally-cooled device, both carbonisation and shrinkage showed logarithmic trends ( R 2 = 0.85–0.98 and R 2 = 0.78–0.94, respectively) based upon delayed carbonisation appearing only 5 min into ablation and onward. For all devices, non-uniform shrinkage was noted within the coagulated area increasing from the boundary of the ablated area (14%) to the limit of carbonisation (39%) in a linear fashion ( R 2 = 0.88) Conclusions: MicrowaveAbstract: Purpose : To evaluate, characterise and compare the extent of tissue shrinkage induced from three different commercial microwave ablation devices, and to elucidate the mechanism behind the distinctive performances obtained. Materials and methods: Microwave ablation ( N = 152) was conducted with three different commercial devices on cubes of ex vivo liver (10–40 ± 2 mm/side) embedded in agar phantoms. 50–60 W was applied for 1–10 min duration. Pre- and post-ablation dimensions of the samples, as well as the extent of carbonisation and coagulation were measured and correlated. ANOVA was performed to evaluate statistical significance. Results: For all devices, logarithmic correlations with time were observed for both tissue shrinkage ( R 2 = 0.84–1.00) and induced carbonisation ( R 2 = 0.73–0.99) radially to the antenna axis. Along the longitudinal axis of the antenna, for two of the devices shrinkage did not appreciably change with time ( p > 0.05), yet carbonisation increased linearly ( R 2 = 0.57–0.94). For the third fully internally-cooled device, both carbonisation and shrinkage showed logarithmic trends ( R 2 = 0.85–0.98 and R 2 = 0.78–0.94, respectively) based upon delayed carbonisation appearing only 5 min into ablation and onward. For all devices, non-uniform shrinkage was noted within the coagulated area increasing from the boundary of the ablated area (14%) to the limit of carbonisation (39%) in a linear fashion ( R 2 = 0.88) Conclusions: Microwave ablation device construction can alter the extent of post-ablation coagulation and tissue shrinkage. Given that tissue shrinkage in the coagulated area shows non-uniform behaviour, observed differences can be attributed in part to the applicator cooling system that alters the ablation temperature profile. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 34:Number 4(2018)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 34:Number 4(2018)
- Issue Display:
- Volume 34, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2018-0034-0004-0000
- Page Start:
- 382
- Page End:
- 391
- Publication Date:
- 2018-05-19
- Subjects:
- Microwave thermal ablation -- tissue shrinkage -- tissue characterisation
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2017.1362115 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6776.xml