High-precision quality assurance of robotic couches with six degrees of freedom. (May 2018)
- Record Type:
- Journal Article
- Title:
- High-precision quality assurance of robotic couches with six degrees of freedom. (May 2018)
- Main Title:
- High-precision quality assurance of robotic couches with six degrees of freedom
- Authors:
- Cheon, Wonjoong
Cho, Junsang
Ahn, Sung Hwan
Han, Youngyih
Choi, Doo Ho - Abstract:
- Highlights: A high precision automatic QA system is developed for robotic couch QA. Visual tracking system (VTS) using motion capture cameras were used. The new system offered QA of yaw, pitch and roll motion and sagging of the couch. The new system has sub-millimeter/degree accuracy. Abstract: A robotic couch capable of six degrees of freedom (6-DoF) of motion was introduced for state-of-the-art radiation therapy. Patient treatment requires precise quality assurance (QA) of 6-DoF. Unfortunately, conventional methods do not provide the requisite accuracy and precision. Therefore, we developed a high-precision automated QA system using a visual tracking system (VTS). The VTS comprises four motion-sensing cameras, a cube with infrared reflective markers. To acquire data in treatment room coordinates, a transformation matrix from VTS coordinates to treatment room coordinates was determined. The mean error and standard deviation of linear and rotational motions, as well as couch sagging were analyzed from continuously acquired images in the moving couch. The accuracy of VTS was 0.024 mm deviation for the sinusoidal motion, and the accuracy of the transformation matrix was 0.02 mm. In a cross-comparison, the difference between Laser Tracker (FARO) measurements was 0.14 ± 0.12 mm for translation and 0.032 ± 0.026° on average for yaw rotation. The new system provides QA of yaw, pitch and roll motion as well as sagging of the couch and sub-millimeter/degree accuracy together withHighlights: A high precision automatic QA system is developed for robotic couch QA. Visual tracking system (VTS) using motion capture cameras were used. The new system offered QA of yaw, pitch and roll motion and sagging of the couch. The new system has sub-millimeter/degree accuracy. Abstract: A robotic couch capable of six degrees of freedom (6-DoF) of motion was introduced for state-of-the-art radiation therapy. Patient treatment requires precise quality assurance (QA) of 6-DoF. Unfortunately, conventional methods do not provide the requisite accuracy and precision. Therefore, we developed a high-precision automated QA system using a visual tracking system (VTS). The VTS comprises four motion-sensing cameras, a cube with infrared reflective markers. To acquire data in treatment room coordinates, a transformation matrix from VTS coordinates to treatment room coordinates was determined. The mean error and standard deviation of linear and rotational motions, as well as couch sagging were analyzed from continuously acquired images in the moving couch. The accuracy of VTS was 0.024 mm deviation for the sinusoidal motion, and the accuracy of the transformation matrix was 0.02 mm. In a cross-comparison, the difference between Laser Tracker (FARO) measurements was 0.14 ± 0.12 mm for translation and 0.032 ± 0.026° on average for yaw rotation. The new system provides QA of yaw, pitch and roll motion as well as sagging of the couch and sub-millimeter/degree accuracy together with precision. … (more)
- Is Part Of:
- Physica medica. Volume 49(2018)
- Journal:
- Physica medica
- Issue:
- Volume 49(2018)
- Issue Display:
- Volume 49, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 49
- Issue:
- 2018
- Issue Sort Value:
- 2018-0049-2018-0000
- Page Start:
- 28
- Page End:
- 33
- Publication Date:
- 2018-05
- Subjects:
- Automatic quality assurance -- Machine quality assurance -- Robotic couch -- Proton therapy -- Stereotactic radiosurgery
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.008 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6801.xml