Pre-treatment verification of lung SBRT VMAT plans with delivery errors: Toward a better understanding of the gamma index analysis. (May 2018)
- Record Type:
- Journal Article
- Title:
- Pre-treatment verification of lung SBRT VMAT plans with delivery errors: Toward a better understanding of the gamma index analysis. (May 2018)
- Main Title:
- Pre-treatment verification of lung SBRT VMAT plans with delivery errors: Toward a better understanding of the gamma index analysis
- Authors:
- Alharthi, Thahabah
Pogson, Elise M.
Arumugam, Sankar
Holloway, Lois
Thwaites, David - Abstract:
- Highlights: Evaluation of ArcCHECK sensitivity for lung SBRT VMAT plans with delivery errors. The gamma (γ) pass rates for these plans exhibited a considerable variation. The majority of errors were not detected using global and local gamma criteria. There was no clear benefit in tightening the gamma criteria in this study. Combining ion chamber measurements with ArcCHECK did not improve error detection. Abstract: Purpose: To study the sensitivity of the ArcCHECK in detecting delivery errors for lung stereotactic body radiotherapy (SBRT) using the Volumetric Modulated Arc Therapy (VMAT) technique and to evaluate the sensitivity of eight global and local gamma tolerances with different cut-off percentages. Methods: Baseline VMAT plans were generated for 15 lung SBRT patients. We delivered the smallest errors(gantry, collimator, and multileaf collimator MLC) which had ≥ ±2% dose difference in the modified treatment plans compared to the baseline plan (the clinical significance of those errors were assessed in our previous study. A total of 100 plan in which 15 baseline plans were measured using the ArcCheck detector along with ion chamber measurements. The sensitivity of the global and local gamma-index method using criteria of 1%/1 mm, 2%/1 mm, 2%/2 mm, and 3%/3 mm was investigated. Results: The gamma (γ) pass rates for these plans exhibited considerable spread. The majority of simulated errors were not detected. Broadly similar detection levels were achieved with theHighlights: Evaluation of ArcCHECK sensitivity for lung SBRT VMAT plans with delivery errors. The gamma (γ) pass rates for these plans exhibited a considerable variation. The majority of errors were not detected using global and local gamma criteria. There was no clear benefit in tightening the gamma criteria in this study. Combining ion chamber measurements with ArcCHECK did not improve error detection. Abstract: Purpose: To study the sensitivity of the ArcCHECK in detecting delivery errors for lung stereotactic body radiotherapy (SBRT) using the Volumetric Modulated Arc Therapy (VMAT) technique and to evaluate the sensitivity of eight global and local gamma tolerances with different cut-off percentages. Methods: Baseline VMAT plans were generated for 15 lung SBRT patients. We delivered the smallest errors(gantry, collimator, and multileaf collimator MLC) which had ≥ ±2% dose difference in the modified treatment plans compared to the baseline plan (the clinical significance of those errors were assessed in our previous study. A total of 100 plan in which 15 baseline plans were measured using the ArcCheck detector along with ion chamber measurements. The sensitivity of the global and local gamma-index method using criteria of 1%/1 mm, 2%/1 mm, 2%/2 mm, and 3%/3 mm was investigated. Results: The gamma (γ) pass rates for these plans exhibited considerable spread. The majority of simulated errors were not detected. Broadly similar detection levels were achieved with the different gamma criteria and cut-offs. Combining ion chamber measurements with ArcCHECK did not improve error detection. Conclusions: Commonly adopted gamma criteria are not sensitive enough to validate lung SBRT VMAT plans at the 2% dose difference level. The error detection levels are fairly consistent despite changes in gamma criteria and cut-offs. The choice of gamma criteria was not significant and there was no clear benefit in tightening the gamma criteria. … (more)
- Is Part Of:
- Physica medica. Volume 49(2018)
- Journal:
- Physica medica
- Issue:
- Volume 49(2018)
- Issue Display:
- Volume 49, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 49
- Issue:
- 2018
- Issue Sort Value:
- 2018-0049-2018-0000
- Page Start:
- 119
- Page End:
- 128
- Publication Date:
- 2018-05
- Subjects:
- Lung SBRT VMAT -- Gamma index -- Delivery error -- ArcCHECK
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.005 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 6801.xml