Errors in 1H‐MRS estimates of brain metabolite concentrations caused by failing to take into account tissue‐specific signal relaxation. (4th May 2018)
- Record Type:
- Journal Article
- Title:
- Errors in 1H‐MRS estimates of brain metabolite concentrations caused by failing to take into account tissue‐specific signal relaxation. (4th May 2018)
- Main Title:
- Errors in 1H‐MRS estimates of brain metabolite concentrations caused by failing to take into account tissue‐specific signal relaxation
- Authors:
- Gasparovic, Charles
Chen, Hongji
Mullins, Paul G. - Abstract:
- Abstract : Accurate measurement of brain metabolite concentrations with proton magnetic resonance spectroscopy ( 1 H‐MRS) can be problematic because of large voxels with mixed tissue composition, requiring adjustment for differing relaxation rates in each tissue if absolute concentration estimates are desired. Adjusting for tissue‐specific metabolite signal relaxation, however, also requires a knowledge of the relative concentrations of the metabolite in gray (GM) and white (WM) matter, which are not known a priori. Expressions for the estimation of the molality and molarity of brain metabolites with 1 H‐MRS are extended to account for tissue‐specific relaxation of the metabolite signals and examined under different assumptions with simulated and real data. Although the modified equations have two unknowns, and hence are unsolvable explicitly, they are nonetheless useful for the estimation of the effect of tissue‐specific metabolite relaxation rates on concentration estimates under a range of assumptions and experimental parameters using simulated and real data. In simulated data using reported GM and WM T 1 and T 2 times for N ‐acetylaspartate (NAA) at 3 T and a hypothetical GM/WM NAA ratio, errors of 6.5–7.8% in concentrations resulted when TR = 1.5 s and TE = 0.144 s, but were reduced to less than 0.5% when TR = 6 s and TE = 0.006 s. In real data obtained at TR/TE = 1.5 s/0.04 s, the difference in the results (4%) was similar to that obtained with simulated data whenAbstract : Accurate measurement of brain metabolite concentrations with proton magnetic resonance spectroscopy ( 1 H‐MRS) can be problematic because of large voxels with mixed tissue composition, requiring adjustment for differing relaxation rates in each tissue if absolute concentration estimates are desired. Adjusting for tissue‐specific metabolite signal relaxation, however, also requires a knowledge of the relative concentrations of the metabolite in gray (GM) and white (WM) matter, which are not known a priori. Expressions for the estimation of the molality and molarity of brain metabolites with 1 H‐MRS are extended to account for tissue‐specific relaxation of the metabolite signals and examined under different assumptions with simulated and real data. Although the modified equations have two unknowns, and hence are unsolvable explicitly, they are nonetheless useful for the estimation of the effect of tissue‐specific metabolite relaxation rates on concentration estimates under a range of assumptions and experimental parameters using simulated and real data. In simulated data using reported GM and WM T 1 and T 2 times for N ‐acetylaspartate (NAA) at 3 T and a hypothetical GM/WM NAA ratio, errors of 6.5–7.8% in concentrations resulted when TR = 1.5 s and TE = 0.144 s, but were reduced to less than 0.5% when TR = 6 s and TE = 0.006 s. In real data obtained at TR/TE = 1.5 s/0.04 s, the difference in the results (4%) was similar to that obtained with simulated data when assuming tissue‐specific relaxation times rather than GM–WM‐averaged times. Using the expressions introduced in this article, these results can be extrapolated to any metabolite or set of assumptions regarding tissue‐specific relaxation. Furthermore, although serving to bound the problem, this work underscores the challenge of correcting for relaxation effects, given that relaxation times are generally not known and impractical to measure in most studies. To minimize such effects, the data should be acquired with pulse sequence parameters that minimize the effect of signal relaxation. Abstract : Expressions for estimating the molality and molarity of brain metabolites with 1 H‐MRS are extended to account for tissue‐specific relaxation of the metabolite signals and examined under different assumptions with simulated and real data. Errors of less than 8% were produced assuming T1 and T2 times for NAA over a range of typical TE and TR values. Using the expressions introduced in this report, these results can be extrapolated to any metabolite or set of assumptions regarding tissue‐specific relaxation. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 31:Number 6(2018)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 31:Number 6(2018)
- Issue Display:
- Volume 31, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 31
- Issue:
- 6
- Issue Sort Value:
- 2018-0031-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-05-04
- Subjects:
- brain -- magnetic resonance spectroscopy -- metabolite relaxation
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3914 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 6739.xml